EUVIMEDEUVIMED entdecken
Fallbericht

Detection of a Silent Hemoglobin Variant During HbA1c Monitoring: the Crucial Role of Capillary Electrophoresis

Tasnim Benlamkaddem, Wafae Rifi, Asmae Biaz, Sanae Bouhsain, Abdellah Dami, Samira Elmachtani Idrissi

Clinical Laboratory · 2026 · 72 (11/2026)

DOI: 10.7754/clin.lab.2025.251223 ↗

Kurz gefasst

Fallbericht in der Zeitschrift Clinical Laboratory, 2026. Verfasst von Tasnim Benlamkaddem und 5 weiteren Autor:innen. Hauptthemen laut MEDLINE: Glycated Hemoglobin.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Hemoglobin A1c (HbA1c) is a widely accepted marker for long-term glycemic control. However, the presence of hemoglobin variants can interfere with its measurement, depending on the analytical method used. Accidental detection of silent variants during HbA1c monitoring is a known challenge in clinical laboratories. METHODS: A 79-year-old male patient with no known history of diabetes or hemoglobinopathy was admitted for chest pain. Routine laboratory tests were performed. HbA1c measurement was initially requested and performed using capillary electrophoresis (Capillarys OCTA 3, Sebia) in HbA1c mode. Confirmatory investigations included hemoglobin electrophoresis in both alkaline and acidic media, as well as High-Performance Liquid Chromatogra-phy (HPLC) using the ADAMS A1c HA-8180V (Arkray). RESULTS: Routine biochemical and hematological parameters were within normal ranges. The initial capillary electrophoresis analysis yielded an atypical electrophoretic profile characterized by split peaks for both HbA0 and HbA1c fractions. A minor abnormal fraction (2.3%) was also detected. Due to this interference, no HbA1c value could be reported. In contrast, further analysis using HPLC and standard gel electrophoresis returned normal results, suggesting the presence of a variant detectable specifically under the separation conditions of the capillary method used. CONCLUSIONS: This case illustrates the potential for analytical interference by a rare hemoglobin variant, which altered the electrophoretic migration of HbA0 and HbA1c in capillary electrophoresis. The discrepancy between techniques highlights the importance of using complementary methods to ensure diagnostic accuracy when an atypical profile is observed. In such situations, alternative markers like fructosamine or glycated albumin should be considered for glycemic monitoring.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Glycated HemoglobinHumansElectrophoresis, CapillaryMaleAgedChromatography, High Pressure Liquid

Substanzen

Glycated Hemoglobinhemoglobin A1c protein, human

Zitieren

APA

Benlamkaddem, T., Rifi, W., Biaz, A., Bouhsain, S., Dami, A., & Idrissi, S. E. (2026). Detection of a Silent Hemoglobin Variant During HbA1c Monitoring: the Crucial Role of Capillary Electrophoresis. Clinical Laboratory, 72(11/2026). https://doi.org/10.7754/clin.lab.2025.251223

Vancouver

Benlamkaddem T, Rifi W, Biaz A, Bouhsain S, Dami A, Idrissi SE. Detection of a Silent Hemoglobin Variant During HbA1c Monitoring: the Crucial Role of Capillary Electrophoresis. Clinical Laboratory. 2026;72(11/2026). doi:10.7754/clin.lab.2025.251223

BibTeX
@article{Benlamkaddem2026,
  author = {Benlamkaddem, Tasnim and Rifi, Wafae and Biaz, Asmae and Bouhsain, Sanae and Dami, Abdellah and Idrissi, Samira Elmachtani},
  title = {Detection of a Silent Hemoglobin Variant During HbA1c Monitoring: the Crucial Role of Capillary Electrophoresis},
  journal = {Clinical Laboratory},
  year = {2026},
  volume = {72},
  number = {11/2026},
  doi = {10.7754/clin.lab.2025.251223}
}
Kostenlos starten →