A Case of Pseudoelevation of Glycosylated Hemoglobin

Gangfeng Li, Hongkun Xu, Yaner Qian, Guoxiang Bao

Clinical Laboratory · 2025

DOI: 10.7754/clin.lab.2024.240808 ↗

Kurz gefasst

Fallbericht in der Zeitschrift Clinical Laboratory, 2025. Verfasst von Gangfeng Li und 3 weiteren Autor:innen. Hauptthemen laut MEDLINE: Electrophoresis, Capillary, Glycated Hemoglobin.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Glycosylated hemoglobin (HbA1c) is a stable compound in human blood that covalently binds the N-terminal valine residue of the β-chain in hemoglobin A to the free aldehyde group of glucose. It can reflect the average blood glucose level of patients in the past 2 - 3 months. Therefore, the accuracy of HbA1c detection results is of great significance for the diagnosis and differential diagnosis of diabetes. METHODS: We report a case of false elevation of HbA1c measured by a high-performance liquid chromatography (HPLC) system. Using different detection platforms and capillary electrophoresis analysis to identify the causes of abnormally elevated HbA1c levels. RESULTS: HbA1c levels decreased to the normal reference range on a different testing platform. Meanwhile, capillary electrophoresis analysis showed the presence of hemoglobin variants. Therefore, the patient's HbA1c result is abnormally elevated, which is considered a pseudo elevation caused by hemoglobin variants. CONCLUSIONS: When HbA1c is abnormally high but there is no clinical symptom of diabetes, the staff should consider the possibility of hemoglobin variants interfering with HbA1c detection. They should simultaneously use different methods to detect HbA1c and conduct hemoglobin component analysis if necessary.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Electrophoresis, CapillaryGlycated HemoglobinHumansBlood GlucoseChromatography, High Pressure LiquidDiabetes Mellitus

Substanzen

Blood GlucoseGlycated Hemoglobinhemoglobin A1c protein, human

Zitieren

APA

Li, G., Xu, H., Qian, Y., & Bao, G. (2025). A Case of Pseudoelevation of Glycosylated Hemoglobin. Clinical Laboratory. https://doi.org/10.7754/clin.lab.2024.240808

Vancouver

Li G, Xu H, Qian Y, Bao G. A Case of Pseudoelevation of Glycosylated Hemoglobin. Clinical Laboratory. 2025. doi:10.7754/clin.lab.2024.240808

BibTeX
@article{Li2025,
  author = {Li, Gangfeng and Xu, Hongkun and Qian, Yaner and Bao, Guoxiang},
  title = {A Case of Pseudoelevation of Glycosylated Hemoglobin},
  journal = {Clinical Laboratory},
  year = {2025},
  doi = {10.7754/clin.lab.2024.240808}
}
Kostenlos starten →