Clinical Applicability of Automated Hematology Analyzer Research Parameters for Disease Diagnosis: a Reference Interval Study

Jiwon Lee, Sangkyoon Hong, Nan Young Kim, Yonggeun Cho, Han-Sung Kim, Hee Jung Kang, Young Kyoung Lee, Miyoung Kim

Clinical Laboratory · 2023

DOI: 10.7754/clin.lab.2022.220620 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Clinical Laboratory, 2023. Verfasst von Jiwon Lee und 7 weiteren Autor:innen. Hauptthemen laut MEDLINE: Appendicitis, Hematology, Myelodysplastic Syndromes, Anemia, Iron-Deficiency.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: We established reference intervals for research parameters of complete blood cell count and examined their usefulness for diagnosing certain diseases. METHODS: Reference intervals for 26 basic and 38 research parameters were established for 3,457 and 1,325 men and 2,742 and 830 women aged 20 - 59 and ≥ 60 years, respectively. Research parameter values for patients with iron deficiency anemia (IDA), appendicitis, sepsis, and myelodysplastic syndromes (MDS) were compared against gender- and age-matched reference values. RESULTS: Seven basic and 10 research parameters among men and one research parameter among women required partitioning by age. No partitioning by gender was required. Further, 67% patients with IDA showed micro red blood cell ratio values above the upper reference limits of their corresponding age and gender subgroups; 3% and 5% patients with appendicitis showed immature granulocyte percentages and counts above the upper reference limits, respectively; 12% - 42% of patients with sepsis showed numerous values exceeded their reference limits, and 67% and 100% patients with MDS showed neutrophil cell complexity and structural dispersion values outside their reference ranges, respectively. CONCLUSIONS: Overall, < 60% of research parameter values were outside their reference ranges among most patients, indicating their limited diagnostic usefulness.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

AppendicitisHematologyMyelodysplastic SyndromesAnemia, Iron-DeficiencyMaleHumansFemaleBlood Cell CountGranulocytesReference Values

Zitieren

APA

Lee, J., Hong, S., Kim, N. Y., Cho, Y., Kim, H. S., Kang, H. J., Lee, Y. K., & Kim, M. (2023). Clinical Applicability of Automated Hematology Analyzer Research Parameters for Disease Diagnosis: a Reference Interval Study. Clinical Laboratory. https://doi.org/10.7754/clin.lab.2022.220620

Vancouver

Lee J, Hong S, Kim NY, Cho Y, Kim HS, Kang HJ, et al. Clinical Applicability of Automated Hematology Analyzer Research Parameters for Disease Diagnosis: a Reference Interval Study. Clinical Laboratory. 2023. doi:10.7754/clin.lab.2022.220620

BibTeX
@article{Lee2023,
  author = {Lee, Jiwon and Hong, Sangkyoon and Kim, Nan Young and Cho, Yonggeun and Kim, Han-Sung and Kang, Hee Jung and Lee, Young Kyoung and Kim, Miyoung},
  title = {Clinical Applicability of Automated Hematology Analyzer Research Parameters for Disease Diagnosis: a Reference Interval Study},
  journal = {Clinical Laboratory},
  year = {2023},
  doi = {10.7754/clin.lab.2022.220620}
}
Kostenlos starten →