The compromise between accuracy and computational cost: system requirements of a markerless motion analysis tool for workload monitoring in tennis
PeerJ · 18.11.2026 · 14 · e21860
DOI: 10.7717/peerj.21860 ↗Kurz gefasst
Fachartikel in der Zeitschrift PeerJ, online erschienen am 18.11.2026. Verfasst von Julie Emmerson und 3 weiteren Autor:innen. Die Arbeit nennt 47 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: EPSRC (Engineering and Physical Sciences Research Council), through CAMERA, the Centre for the Analysis of Motion, Entertainment Research and Applications.
Abstract (Originalsprache)
Background
Markerless motion capture can provide a novel method for workload monitoring in tennis, with mechanical work (external and internal components) previously presented as a suitable metric. However, markerless methods typically involve large amounts of raw data and long data processing times, hence this is currently an impractical solution. Therefore, this study investigated the effects of reducing system specifications, with the aim of finding a compromise between computational cost and accuracy that is suitable for use in applied settings.
Methods
Video data of 15 tennis players completing an on-court fatiguing protocol were processed with a markerless motion analysis pipeline (based on open-source pose estimation) to calculate mechanical work. Eight cameras operating at a frame rate of 200 Hz and 1,920 × 1,080 resolution were used. Data were reprocessed using fewer cameras, lower frame rates and lower resolutions.
Results
Reducing the number of cameras, even by one, or resolution resulted in large drop-offs in performance, related to erroneous initial pose estimation, with root mean squared differences (RMSD) of ∼160% (external) and ∼150% (internal) when using four cameras and ∼640% (external) and ∼190% (internal) when using quarter resolution videos. Conversely, frame rates of 50 and 100 Hz were deemed acceptable for calculating external (RMSD: 1.4%) and internal (RMSD: 0.9%) work respectively. Reducing the frame rate was also associated with the largest reduction in computational cost, with data saving and processing times approximately proportional to the number of frames.
Conclusion
Within the conditions examined, reducing the number of cameras or resolution was not an option due to inaccuracies of the open-source pose estimation algorithm, but utilising a lower frame rate appears to offer a promising compromise between computational efficiency and measurement accuracy, potentially increasing the viability of markerless motion capture as a solution for in-field workload monitoring.
Förderung
- EPSRC (Engineering and Physical Sciences Research Council), through CAMERA, the Centre for the Analysis of Motion, Entertainment Research and Applications
Zitieren
APA
Emmerson, J., Needham, L., Williams, S., & Colyer, S. (2026). The compromise between accuracy and computational cost: system requirements of a markerless motion analysis tool for workload monitoring in tennis. PeerJ, 14, e21860. https://doi.org/10.7717/peerj.21860
Vancouver
Emmerson J, Needham L, Williams S, Colyer S. The compromise between accuracy and computational cost: system requirements of a markerless motion analysis tool for workload monitoring in tennis. PeerJ. 2026;14:e21860. doi:10.7717/peerj.21860
BibTeX
@article{Emmerson2026,
author = {Emmerson, Julie and Needham, Laurie and Williams, Sean and Colyer, Steffi},
title = {The compromise between accuracy and computational cost: system requirements of a markerless motion analysis tool for workload monitoring in tennis},
journal = {PeerJ},
year = {2026},
volume = {14},
pages = {e21860},
doi = {10.7717/peerj.21860}
}
EUVIMED