Comparing the Accuracy of Markerless Motion Analysis and Optoelectronic System for Measuring Gait Kinematics of Lower Limb

Luca Emanuele Molteni iD, Giuseppe Andreoni iD

Bioengineering · 16.04.2025 · 12 (4) · 424

DOI: 10.3390/bioengineering12040424 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Bioengineering, online erschienen am 16.04.2025. Verfasst von Luca Emanuele Molteni und 1 weiteren Autor:innen. Beteiligte Einrichtung: Scientific Institute IRCCS "E. Medea", Bosisio Parini, 23842 Lecco, Italy. Die Arbeit wurde bisher 18-mal zitiert (Crossref) und nennt 44 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: 5 per mille, Italian Ministry of Health.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

(1)

Background

Marker-based optical motion tracking is the gold standard in gait analysis; however, markerless solutions are rapidly emerging today. Algorithms like Openpose can track human movement from a video. Few studies have assessed the validity of this method. This study aimed to assess the reliability of Openpose in measuring the kinematics and spatiotemporal gait parameters. (2)

Methods

This analysis used simultaneously recorded video and optoelectronic motion capture data. We assessed 20 subjects with different gait impairments (healthy, right hemiplegia, left hemiplegia, paraparesis). The two methods were compared using computing absolute errors (AEs), intraclass correlation coefficients (ICCs), and cross-correlation coefficients (CCs) for normalized gait cycle joint angles. (3)

Results

The spatiotemporal parameters showed an ICC between good to excellent, and the absolute error was very small: cadence AE = 1.63 step/min, Mean Velocity AE = 0.16 m/s. The Range of Motion (ROM) showed a good to excellent agreement in the sagittal plane. Furthermore, the normalized gait cycle CCC values indicated moderate to strong coupling in the sagittal plane. (4)

Conclusions

We found Openpose to be accurate for sagittal plane gait kinematics and for spatiotemporal gait parameters in the healthy and pathological subjects assessed.

Schlagwörter

Stichwörter der Autor:innen

Openposekinematicmarkerlesspediatric

Autor:innen und Institutionen

  • Scientific Institute IRCCS "E. Medea", Bosisio Parini, 23842 Lecco, Italy.
  • Department of Design, Politecnico di Milano, 20133 Milano, Italy.

ORCID-Profile: Luca Emanuele Molteni, Giuseppe Andreoni

Förderung

  • 5 per mille
  • Italian Ministry of Health

Zitieren

APA

Molteni, L. E., & Andreoni, G. (2025). Comparing the Accuracy of Markerless Motion Analysis and Optoelectronic System for Measuring Gait Kinematics of Lower Limb. Bioengineering, 12(4), 424. https://doi.org/10.3390/bioengineering12040424

Vancouver

Molteni LE, Andreoni G. Comparing the Accuracy of Markerless Motion Analysis and Optoelectronic System for Measuring Gait Kinematics of Lower Limb. Bioengineering. 2025;12(4):424. doi:10.3390/bioengineering12040424

BibTeX
@article{Molteni2025,
  author = {Molteni, Luca Emanuele and Andreoni, Giuseppe},
  title = {Comparing the Accuracy of Markerless Motion Analysis and Optoelectronic System for Measuring Gait Kinematics of Lower Limb},
  journal = {Bioengineering},
  year = {2025},
  volume = {12},
  number = {4},
  pages = {424},
  doi = {10.3390/bioengineering12040424}
}