EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

MultNAT HIV-1 Viral Load Assay: a simple, rapid and sensitive cross-primer amplification assay for detecting the HIV-1 virus in the field

Lili Huang, Zhongbao Zuo, Lanlan Hu, Jing Wu, Qingting Bu, Yueping Li, Xiuhui Li, Yanqiong Zhou, Aifang Xu

PeerJ · 2025

DOI: 10.7717/peerj.19753 ↗

Kurz gefasst

Fachartikel in der Zeitschrift PeerJ, 2025. Verfasst von Lili Huang und 8 weiteren Autor:innen. Beteiligte Einrichtung: Clinical Laboratory, Hangzhou Xixi Hospital, Hangzhou, Zhejiang Province, China. Hauptthemen laut MEDLINE: Viral Load, HIV-1, HIV Infections. Die Arbeit nennt 25 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Hangzhou Biomedical and Health Industry Development Support Science and Technology.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

A large number of new human immunodeficiency virus (HIV) patients are diagnosed worldwide every year. This study aimed to design a rapid, efficient, and convenient kit for detecting HIV-1 viral load.

Methods

The sensitivity and specificity of the kit were determined, and serum samples were collected from HIV-negative and HIV-positive individuals who underwent medical checkups at Xixi Hospital in Hangzhou City, Zhejiang Province, China, between June and August 2023 for testing. The presence of HIV-1 in the clinical samples was assessed via a diagnostic PCR system and a conventional fluorescent quantitative PCR technique in this study.

Results

HIV-1 RNA was measured with a 100 copies/mL sensitivity via the MultNAT HIV-1 Viral Load Assay. The accuracy of the a ssay was as follows: The assay showed near-perfect agreement with compare kit (kappa = 0.9945), positive compliance rate of 99.45% (182/183), negative compliance rate of 100% (183/183). The linear correlation coefficient between MultNAT HIV-1 Viral Load Assay and DaAn kit was 0.95, and the R2 was 0.90.

Conclusion

Due to its simplicity, rapid response time, and high sensitivity and specificity, the MultNAT HIV-1 Viral Load Assay is suitable for primary care and epidemiological screening, facilitating rapid and accurate HIV-1 detection.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Viral LoadHIV-1HIV InfectionsHumansSensitivity and SpecificityChinaRNA, ViralReagent Kits, DiagnosticFemaleMaleAdult

Stichwörter der Autor:innen

Epidemiological screeningHuman immunodeficiency virusMultNAT HIV-1 viral load assayPrimary care

Substanzen

RNA, ViralReagent Kits, Diagnostic

Autor:innen und Institutionen

  • Clinical Laboratory, Hangzhou Xixi Hospital, Hangzhou, Zhejiang Province, China.
  • Clinical Laboratory, Ustar Biotechnologies, Hangzhou, Zhejiang Province, China.

Förderung

  • Hangzhou Biomedical and Health Industry Development Support Science and Technology

Zitieren

APA

Huang, L., Zuo, Z., Hu, L., Wu, J., Bu, Q., Li, Y., Li, X., Zhou, Y., & Xu, A. (2025). MultNAT HIV-1 Viral Load Assay: a simple, rapid and sensitive cross-primer amplification assay for detecting the HIV-1 virus in the field. PeerJ. https://doi.org/10.7717/peerj.19753

Vancouver

Huang L, Zuo Z, Hu L, Wu J, Bu Q, Li Y, et al. MultNAT HIV-1 Viral Load Assay: a simple, rapid and sensitive cross-primer amplification assay for detecting the HIV-1 virus in the field. PeerJ. 2025. doi:10.7717/peerj.19753

BibTeX
@article{Huang2025,
  author = {Huang, Lili and Zuo, Zhongbao and Hu, Lanlan and Wu, Jing and Bu, Qingting and Li, Yueping and Li, Xiuhui and Zhou, Yanqiong and Xu, Aifang},
  title = {MultNAT HIV-1 Viral Load Assay: a simple, rapid and sensitive cross-primer amplification assay for detecting the HIV-1 virus in the field},
  journal = {PeerJ},
  year = {2025},
  doi = {10.7717/peerj.19753}
}
Kostenlos starten →