A comparative performance evaluation of 12 HIV-1 viral load testing asssays: advancing the clinical application of HIV-1 nucleic acid testing in China

Yu Wang iD, Pinliang Pan, Wenge Xing, Xin Zhang, Boxue Han, Cong Jin

Microbiology Spectrum · 2025

DOI: 10.1128/spectrum.03218-24 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Microbiology Spectrum, 2025. Verfasst von Yu Wang und 5 weiteren Autor:innen. Beteiligte Einrichtung: National Key Laboratory of Intelligent Tracking and Forecasting for Infectious Diseases, National Center for AIDS/STD Control and Prevention, Chinese…. Hauptthemen laut MEDLINE: Viral Load, HIV-1, HIV Infections, Reagent Kits, Diagnostic. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 27 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Natural Science Foundation of Beijing Municipality.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

HIV-1 viral load testing serves as a critical tool for monitoring antiretroviral therapy efficacy and detecting acute HIV-1 infections. This study evaluated the precision, linearity, and clinical performance of 12 commonly used HIV-1 viral load testing kits in China (including seven domestic and five imported kits). Precision analysis revealed that 11 kits achieved intra-assay coefficients of variation (CV%) below 5% for high and medium concentration standards at 10,000 and 1,000 IU/mL, respectively, while only 4 kits maintained comparable precision at low concentration standards (100 IU/mL). All kits showed excellent linear performance across their dynamic ranges (R² = 0.9924–0.9999) and effectively covered the major HIV-1 subtypes circulating in China. Correlation analysis of clinical samples showed strong associations (R² >0.70) in 49 out of 66 kit-pair comparisons, with Bland-Altman agreement analysis confirming good consistency between different kits. Notably, domestic Kit B exhibited minimal deviation (0.004 log10 IU/mL) compared to leading imported assays. Point-of-care testing kits demonstrated performance comparable to laboratory-based systems. However, observed variability in low viral load quantification highlights the need for improved precision to meet stringent clinical requirements for viral suppression monitoring at 50 copies/mL. These findings validate the reliability of domestic kits for clinical application while suggesting further enhancement in low-level viremia detection capabilities. IMPORTANCE HIV-1 viral load (VL) testing is extremely important in monitoring the efficacy of antiretroviral therapy and diagnosing acute HIV-1 infections. In China, the growing demand for nucleic acid testing (NAT) and rapid development of HIV-1 NAT technology have led to the approval of 15 HIV-1 VL kits by 2024, but their performance remains understudied. This study comprehensively evaluates 12 widely used HIV-1 VL kits (seven domestic and five imported) in China, demonstrating high precision, linearity, and clinical accuracy across prevalent HIV-1 subtypes in China. Notably, domestic kits exhibited a strong correlation with imported kits, validating their reliability for clinical use. However, variability in low VL quantification highlights challenges in meeting the stringent suppression threshold of 50 copies/mL. These findings provide evidence for optimizing HIV-1 NAT strategies, supporting the adoption of cost-effective domestic kits, and guiding future improvements for low-level viremia monitoring.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Viral LoadHIV-1HIV InfectionsReagent Kits, DiagnosticHumansChinaRNA, ViralReproducibility of Results

Stichwörter der Autor:innen

HIV-1 viral load testinglow-level viremianucleic acid testingperformance evaluationpoint-of-care testing

Substanzen

Reagent Kits, DiagnosticRNA, Viral

Autor:innen und Institutionen

  • National Key Laboratory of Intelligent Tracking and Forecasting for Infectious Diseases, National Center for AIDS/STD Control and Prevention, Chinese Center for Disease Control and Prevention, Beijing, China.

ORCID-Profile: Yu Wang

Förderung

  • Natural Science Foundation of Beijing Municipality

Zitieren

APA

Wang, Y., Pan, P., Xing, W., Zhang, X., Han, B., & Jin, C. (2025). A comparative performance evaluation of 12 HIV-1 viral load testing asssays: advancing the clinical application of HIV-1 nucleic acid testing in China. Microbiology Spectrum. https://doi.org/10.1128/spectrum.03218-24

Vancouver

Wang Y, Pan P, Xing W, Zhang X, Han B, Jin C. A comparative performance evaluation of 12 HIV-1 viral load testing asssays: advancing the clinical application of HIV-1 nucleic acid testing in China. Microbiology Spectrum. 2025. doi:10.1128/spectrum.03218-24

BibTeX
@article{Wang2025,
  author = {Wang, Yu and Pan, Pinliang and Xing, Wenge and Zhang, Xin and Han, Boxue and Jin, Cong},
  title = {A comparative performance evaluation of 12 HIV-1 viral load testing asssays: advancing the clinical application of HIV-1 nucleic acid testing in China},
  journal = {Microbiology Spectrum},
  year = {2025},
  doi = {10.1128/spectrum.03218-24}
}
Kostenlos starten →