EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

SplintR ligation-triggered in-situ rolling circle amplification on magnetic bead for accurate detection of circulating microRNAs

Sha Yang, Lijia Yuan, Xing Luo, Ting Xiao, Xiaoqing Sun, Liu Feng, Jiezhong Deng, Mei Zhan

PeerJ · 2025

DOI: 10.7717/peerj.19082 ↗

Kurz gefasst

Fachartikel in der Zeitschrift PeerJ, 2025. Verfasst von Sha Yang und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Clinical Laboratory Medicine, Southwest Hospital, The Third Military Medical University, Shapingba District, Chongqing, China. Hauptthemen laut MEDLINE: Nucleic Acid Amplification Techniques, Circulating MicroRNA, MicroRNAs, Biosensing Techniques. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 36 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Key Research and Development Program of China, National Natural Science Foundation of China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The circulating microRNAs (miRNAs), endogenous noncoding RNAs, post-transcriptionally participate in multiple processes during cell growth and development. Moreover, dysregulation of miRNAs expression is intricately associated with cancer. Currently, challenges of high homology, sequence similarity, and low abundance encountered in the detection of target miRNAs in complex samples need to be addressed. Biosensors established for miRNAs detection suffer from limitations in terms of sensitivity, specificity and high cost. Herein, a miRNA detection method based on in-situ RCA on magnetic bead catalyzed by SplintR ligase was proposed to achieve high sensitivity and high specificity. The following steps are included: (1) formation of P1-P2-miRNA double-stranded complex under catalyzation of SplintR ligase, and the release of P1-P2 single strand under denaturation; (2) enrichment of P1-P2 single chain by streptavidin-modified magnetic beads (SM-MB); (3) in situ RCA on surface of magnetic beads; (4) fluorescence detection. After optimization of experimental conditions, miRNA-155 detection with improved sensitivity and specificity was achieved. The detection limit was low to 36.39 fM, and one-base mismatch discrimination was demonstrated. Also, the clinical practicability for circulating miRNA-155 detection was preliminarily validated in human serum samples.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Nucleic Acid Amplification TechniquesCirculating MicroRNAMicroRNAsBiosensing TechniquesHumansLimit of DetectionSensitivity and SpecificityMagnetics

Stichwörter der Autor:innen

Circulating microRNAs detectionIn-situ rolling circle amplificationSplintR

Substanzen

Circulating MicroRNAMicroRNAsMIRN155 microRNA, human

Autor:innen und Institutionen

  • Department of Clinical Laboratory Medicine, Southwest Hospital, The Third Military Medical University, Shapingba District, Chongqing, China.
  • Shigatse Branch, Xinqiao Hospital, The Third Military Medical University, Shigatse, Xizang Province, China.
  • Emergency Department, Southwest Hospital, The Third Military Medical University, Shapingba District, Chongqing, China.
  • Department of Orthopedics, Southwest Hospital, The Third Military Medical University, Shapingba District, Chongqing, China.
  • Nan'an District People's Hospital of Chongqing, Nan'an District, Chongqing, China.

Förderung

  • National Key Research and Development Program of China
  • National Natural Science Foundation of China

Zitieren

APA

Yang, S., Yuan, L., Luo, X., Xiao, T., Sun, X., Feng, L., Deng, J., & Zhan, M. (2025). SplintR ligation-triggered in-situ rolling circle amplification on magnetic bead for accurate detection of circulating microRNAs. PeerJ. https://doi.org/10.7717/peerj.19082

Vancouver

Yang S, Yuan L, Luo X, Xiao T, Sun X, Feng L, et al. SplintR ligation-triggered in-situ rolling circle amplification on magnetic bead for accurate detection of circulating microRNAs. PeerJ. 2025. doi:10.7717/peerj.19082

BibTeX
@article{Yang2025,
  author = {Yang, Sha and Yuan, Lijia and Luo, Xing and Xiao, Ting and Sun, Xiaoqing and Feng, Liu and Deng, Jiezhong and Zhan, Mei},
  title = {SplintR ligation-triggered in-situ rolling circle amplification on magnetic bead for accurate detection of circulating microRNAs},
  journal = {PeerJ},
  year = {2025},
  doi = {10.7717/peerj.19082}
}