EUVIMEDEUVIMED entdecken
Multizentrische StudieRandomisierte kontrollierte Studie

Low-Volume Polyethylene Glycol for Bowel Preparation in Hospitalized Adults

Leonardo Frazzoni, Paola Cesaro iD, Franco Radaelli iD, Carlo Fabbri, Simona Guglielmo, Alessandro Mussetto iD, Mauro Manno iD, Cecilia Lina Pugliano iD, Francesco Segatta, Edoardo Pezzuto iD, Emanuel Raschi iD, Antonio Facciorusso iD und 4 weitere

Annals of Internal Medicine · 2026

DOI: 10.7326/annals-25-05005 ↗

Kurz gefasst

Multizentrische Studie in der Zeitschrift Annals of Internal Medicine, 2026. Verfasst von Leonardo Frazzoni und 15 weiteren Autor:innen. Beteiligte Einrichtung: Department of Medical and Surgical Sciences, University of Bologna, Bologna, Italy; and Gastroenterology and Endoscopy Unit, Rimini, Italy (L.Frazzon…. Hauptthemen laut MEDLINE: Polyethylene Glycols, Colonoscopy, Cathartics. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 19 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Adequate bowel preparation is essential for high-quality colonoscopy but remains challenging in hospitalized patients, and comparative data on preparation volume are limited. OBJECTIVE: To compare the efficacy, tolerability, and safety of very low-volume (1-liter [1L]), low-volume (2-liter [2L]), and high-volume (4-liter [4L]) polyethylene glycol (PEG) regimens for inpatient colonoscopy preparation. DESIGN: Multicenter, randomized controlled, endoscopist-blinded trial. (EudraCT: 2019-002799-15; ClinicalTrials.gov: NCT04708366). SETTING: Community and academic hospitals in Italy. PATIENTS: Hospitalized adults undergoing elective colonoscopy. INTERVENTION: Patients were randomly assigned (1:1:1) to split-dose 1L PEG-ascorbate, 2L PEG-ascorbate, or 4L PEG. MEASUREMENTS: Primary end point was adequate bowel cleansing (Boston Bowel Preparation Scale [BBPS] score ≥6 with all segments ≥2). Secondary end points included high-quality cleansing (BBPS score, 8 to 9), high-quality right-colon cleansing (BBPS score, 3), and willingness to repeat. RESULTS: Among 665 randomly assigned patients (1L, n = 228; 2L, n = 218; 4L, n = 219), adequate overall cleansing occurred in 82.0%, 78.0%, and 78.5% (absolute difference between the 1L and 2L groups [Δ1L-2L], 4.0 percentage points [95% CI, -3.4 to 11.4 percentage points]; absolute difference between the 1L and 4L groups [Δ1L-4L], 3.5 percentage points [CI, -3.9 to 10.9 percentage points]). High-quality overall cleansing occurred in 46.9%, 35.3%, and 37.4% (Δ1L-2L, 11.6 percentage points [CI, 2.5 to 20.5 percentage points]; Δ1L-4L, 9.5 percentage points [CI, 0.3 to 18.5 percentage points]). High-quality right-colon cleansing occurred in 40.6%, 29.5%, and 31.6% (Δ1L-2L, 11.2 percentage points [CI, 2.1 to 20.0 percentage points]; Δ1L-4L, 9.0 percentage points [CI, 0.0 to 17.9 percentage points]). Tolerability was good across regimens, with the highest willingness to repeat in the 1L group (84.2%), despite more frequent vomiting and thirst. LIMITATION: Patients requiring urgent colonoscopy for active gastrointestinal bleeding and those with severe/unstable comorbid conditions were excluded. CONCLUSION: In hospitalized adults undergoing elective colonoscopy, 1L PEG-ascorbate yielded higher rates of high-quality cleansing, including right colon, than 2L PEG-ascorbate and 4L PEG, with similar rates of adequate cleansing and high willingness to repeat. PRIMARY FUNDING SOURCE: Norgine Srl.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Polyethylene GlycolsColonoscopyCatharticsHumansFemaleMiddle AgedAgedMaleAscorbic AcidAdult

Substanzen

Polyethylene GlycolsCatharticsAscorbic Acid

Autor:innen und Institutionen

  • Department of Medical and Surgical Sciences, University of Bologna, Bologna, Italy; and Gastroenterology and Endoscopy Unit, Rimini, Italy (L.Frazzoni).
  • Gastroenterology and Digestive Endoscopy Unit, Fondazione Poliambulanza Istituto Ospedaliero, Brescia, Italy (P.C., C.L.P., E.P.).
  • Department of Gastroenterology, Valduce Hospital, Como, Italy (F.R., F.S.).
  • Digestive Endoscopy and Gastroenterology Unit, Forlì-Cesena Hospitals, Azienda Unita Sanitaria Locale della Romagna, Forlì-Cesena, Italy (C.F.).
  • Gastroenterology Unit, Hospital of Imola, University of Bologna, Imola, Italy (S.G.).
  • Gastroenterology Unit, Azienda Unità Sanitaria Locale della Romagna, Santa Maria delle Croci Hospital, Ravenna, Italy (A.M.).

ORCID-Profile: Paola Cesaro, Franco Radaelli, Alessandro Mussetto, Mauro Manno, Cecilia Lina Pugliano, Edoardo Pezzuto, Emanuel Raschi, Antonio Facciorusso, Lorenzo Fuccio

Zitieren

APA

Frazzoni, L., Cesaro, P., Radaelli, F., Fabbri, C., Guglielmo, S., Mussetto, A., Manno, M., Pugliano, C. L., Segatta, F., Pezzuto, E., Raschi, E., Facciorusso, A., Hassan, C., Spada, C., Fuccio, L., & INTERPRET Study Group (2026). Low-Volume Polyethylene Glycol for Bowel Preparation in Hospitalized Adults. Annals of Internal Medicine. https://doi.org/10.7326/annals-25-05005

Vancouver

Frazzoni L, Cesaro P, Radaelli F, Fabbri C, Guglielmo S, Mussetto A, et al. Low-Volume Polyethylene Glycol for Bowel Preparation in Hospitalized Adults. Annals of Internal Medicine. 2026. doi:10.7326/annals-25-05005

BibTeX
@article{Frazzoni2026,
  author = {Frazzoni, Leonardo and Cesaro, Paola and Radaelli, Franco and Fabbri, Carlo and Guglielmo, Simona and Mussetto, Alessandro and Manno, Mauro and Pugliano, Cecilia Lina and Segatta, Francesco and Pezzuto, Edoardo and Raschi, Emanuel and Facciorusso, Antonio and Hassan, Cesare and Spada, Cristiano and Fuccio, Lorenzo and INTERPRET Study Group, INTERPRET Study Group},
  title = {Low-Volume Polyethylene Glycol for Bowel Preparation in Hospitalized Adults},
  journal = {Annals of Internal Medicine},
  year = {2026},
  doi = {10.7326/annals-25-05005}
}
Kostenlos starten →