Useful Bowel Preparation with Ultralow-Volume (500 mL) Polyethylene Glycol for Colonoscopy: A Retrospective Study
Digestive Diseases · 2025
DOI: 10.1159/000543858 ↗Kurz gefasst
Fachartikel in der Zeitschrift Digestive Diseases, 2025. Verfasst von Yusuke Mizuno und 13 weiteren Autor:innen. Beteiligte Einrichtung: Department of Gastroenterology and Metabolism, Nagoya City University Graduate School of Medical Sciences, Nagoya, Japan. Hauptthemen laut MEDLINE: Colonoscopy, Polyethylene Glycols, Cathartics. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 30 Literaturangaben.
Abstract (Originalsprache)
Introduction
Adequate bowel preparation is indispensable for high-quality colonoscopy. We have developed an ultralow-volume (500 mL) polyethylene glycol (PEG) combined with other laxatives (sennoside, sodium picosulfate, and lactulose) and applied this regimen clinically to all patients with colonoscopy for 3 decades. This study aimed to assess the effectiveness of this ultralow-volume bowel preparation regimen.
Methods
This single-center, retrospective study analyzed data from consecutive outpatients who underwent colonoscopy between January 2022 and December 2022. All the patients took sennoside (24 mg) two nights before, sodium picosulfate (75 mg) one night before, and 500 mL of PEG with lactulose (58.5 g) on the day of examination. Cleaning efficacy was evaluated using the Boston Bowel Preparation Scale (BBPS). Adequate bowel preparation was defined as a total BBPS score ≥6, with all colon segments scoring ≥2.
Results
Out of 862 patients with colonoscopy, 773 were eligible for this study, and the median age was 66 years. The adequate bowel preparation rate was 91.8% (710/773). Notably, the BBPS full score “9” was observed in 50.5% (390/773). The median cecal intubation time and examination time were 8 and 20 min, respectively. Only 3 patients vomited as a side effect. In the multivariate analysis, age ≥70 years, diabetes mellitus, and diverticula were significantly independent risk factors for inadequate bowel preparation.
Conclusions
Our established ultralow-volume (500 mL) PEG is safe and useful as a bowel preparation method.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Gastroenterology and Metabolism, Nagoya City University Graduate School of Medical Sciences, Nagoya, Japan.
Zitieren
APA
Mizuno, Y., Shimura, T., Nukui, T., Uno, K., Nishigaki, R., Kojima, Y., Kanno, T., Sasaki, M., Fukusada, S., Sugimura, N., Tanaka, M., Ozeki, K., Kubota, E., & Kataoka, H. (2025). Useful Bowel Preparation with Ultralow-Volume (500 mL) Polyethylene Glycol for Colonoscopy: A Retrospective Study. Digestive Diseases. https://doi.org/10.1159/000543858
Vancouver
Mizuno Y, Shimura T, Nukui T, Uno K, Nishigaki R, Kojima Y, et al. Useful Bowel Preparation with Ultralow-Volume (500 mL) Polyethylene Glycol for Colonoscopy: A Retrospective Study. Digestive Diseases. 2025. doi:10.1159/000543858
BibTeX
@article{Mizuno2025,
author = {Mizuno, Yusuke and Shimura, Takaya and Nukui, Takayuki and Uno, Konomu and Nishigaki, Ruriko and Kojima, Yuki and Kanno, Takuya and Sasaki, Makiko and Fukusada, Shigeki and Sugimura, Naomi and Tanaka, Mamoru and Ozeki, Keiji and Kubota, Eiji and Kataoka, Hiromi},
title = {Useful Bowel Preparation with Ultralow-Volume (500 mL) Polyethylene Glycol for Colonoscopy: A Retrospective Study},
journal = {Digestive Diseases},
year = {2025},
doi = {10.1159/000543858}
}
EUVIMED