EUVIMEDOpdag EUVIMED
Crossref

Assessing accuracy of automated cell counters for mammalian cell culture

Meghana Kasturi, KORMOS, NICOLE, Perla Fares, HINOJOSA, ALEJANDRO, Caymen M. Novak

Deep Blue (University of Michigan) · 2025-04-21

DOI: 10.7302/25358 ↗

At a glance

Journal article in Deep Blue (University of Michigan), published on 2025-04-21. Written by Meghana Kasturi and 6 co-authors.

AbstractSubjectsBibliografiske oplysningerCiteRelated studies

Abstract (original language)

Accurate quantification of cell populations is essential for a wide range of biological and clinical applications; however, the efficacy of cell counting technologies can differ substantially based on cellular morphology, cell concentration, cell counting technique (manual or automated), imaging technique and the algorithm used to quantify the cells. This investigation assesses the precision, consistency and accuracy of four automated cell counters in comparison to the conventional hemocytometer, focusing on two critical factors: morphology (rounded versus non-rounded cells) and cell size. The outcomes obtained from the four automated cell counters are evaluated based on the following parameters: Total cell count, Live cell count, dead cell count and cell viability across low, medium, and high cell concentrations. The discussion will address any significant differences among these devices that enhance the accuracy of cell counting across various morphologies. The outcomes emphasize the necessity of selecting suitable cell counting techniques that align with the specific attributes of the cell population, providing crucial insights for researchers and clinicians striving to enhance experimental reproducibility and maintain data integrity.

Subjects

automated cell countermammalian cell culturecell viabilitycell morphologycell sizecell densityimage analysis algorithms

Cite

APA

Kasturi, M., KORMOS, NICOLE, Fares, P., HINOJOSA, ALEJANDRO, & Novak, C. M. (2025). Assessing accuracy of automated cell counters for mammalian cell culture. Deep Blue (University of Michigan). https://doi.org/10.7302/25358

Vancouver

Kasturi M, KORMOS, NICOLE, Fares P, HINOJOSA, ALEJANDRO, et al. Assessing accuracy of automated cell counters for mammalian cell culture. Deep Blue (University of Michigan). 2025. doi:10.7302/25358

BibTeX
@article{Kasturi2025,
  author = {Kasturi, Meghana and KORMOS and NICOLE and Fares, Perla and HINOJOSA and ALEJANDRO and Novak, Caymen M.},
  title = {Assessing accuracy of automated cell counters for mammalian cell culture},
  journal = {Deep Blue (University of Michigan)},
  year = {2025},
  doi = {10.7302/25358}
}
Start for free →