Ultrasound flow imaging for assessing cerebrovascular changes following focused-ultrasound blood-brain barrier opening
Theranostics · 22.09.2025 · 15 (18) · 10028-10044
DOI: 10.7150/thno.98098 ↗Kurz gefasst
Fachartikel in der Zeitschrift Theranostics, erschienen am 22.09.2025. Verfasst von Sua Bae und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Biomedical Engineering, Columbia University, New York, NY, USA. Hauptthemen laut MEDLINE: Blood-Brain Barrier, Cerebrovascular Circulation. Die Arbeit wurde bisher 7-mal zitiert (Crossref). Der Volltext ist frei in PubMed Central verfügbar.
Abstract (Originalsprache)
Rationale
Microbubble-mediated focused ultrasound (Mb-FUS) is a promising non-invasive technique for blood-brain barrier opening (BBBO), enhancing drug delivery and immunomodulation for brain disease treatments. In Mb-FUS, microbubble cavitation exerts mechanical stress on blood vessel walls. While cavitation is commonly used for monitoring, leveraging the vascular response to predict treatment outcomes remains unexplored. This study pioneers the use of ultrasound flow imaging with microbubbles to investigate the cerebrovascular changes induced by Mb-FUS and assesses the feasibility of this imaging technique for predicting BBBO treatment outcomes.
Methods
We utilized contrast-enhanced power Doppler (CEPD) and ultrasound localization microscopy (ULM) to monitor and quantify Mb-FUS-induced cerebrovascular changes in mice (n=4 without skull, n=12 with skull). The left hippocampus/thalamus regions were targeted for Mb-FUS BBBO. Pre- and post-FUS images were acquired, with continuous monitoring of CEPD intensity to ensure consistency in microbubble concentration. We observed changes in the number of microbubbles detected, their speeds, and vessel diameter after Mb-FUS.
Results
Reductions in blood volume, vessel diameter, and flow speed were observed in the sonicated regions. We demonstrated the transcranial capability of CEPD and ULM to detect Mb-FUS-induced vascular changes by observing linear relationships between the reductions in blood volume and flow, and the size of the opening or edema. Furthermore, local signal reduction detected by transcranial CEPD map spatially co-localized with the edema region identified in T2-weighted MRI.
Conclusion
We have developed a method to quantify changes in blood volume, flow speed, and vessel diameter following Mb-FUS using ultrasound flow imaging (CEPD and ULM) with microbubbles. For the first time, the blood vessels post-FUS were assessed by ultrasound flow imaging that visualizes associated vascular changes and potential damage. This technique not only holds potential for predicting treatment outcomes but also paves the way for a unified ultrasound-based system for both treatment and monitoring, with potential for future clinical translation.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Biomedical Engineering, Columbia University, New York, NY, USA.
- Department of Radiology, Columbia University, New York, NY, USA.
Zitieren
APA
Bae, S., Lee, S. A., Kim, S., Tsitsos, F., Liu, Y., & Konofagou, E. E. (2025). Ultrasound flow imaging for assessing cerebrovascular changes following focused-ultrasound blood-brain barrier opening. Theranostics, 15(18), 10028-10044. https://doi.org/10.7150/thno.98098
Vancouver
Bae S, Lee SA, Kim S, Tsitsos F, Liu Y, Konofagou EE. Ultrasound flow imaging for assessing cerebrovascular changes following focused-ultrasound blood-brain barrier opening. Theranostics. 2025;15(18):10028-10044. doi:10.7150/thno.98098
BibTeX
@article{Bae2025,
author = {Bae, Sua and Lee, Stephen A and Kim, Seongyeon and Tsitsos, Fotios and Liu, Yangpei and Konofagou, Elisa E},
title = {Ultrasound flow imaging for assessing cerebrovascular changes following focused-ultrasound blood-brain barrier opening},
journal = {Theranostics},
year = {2025},
volume = {15},
number = {18},
pages = {10028--10044},
doi = {10.7150/thno.98098}
}
EUVIMED