Effect of Microbubble Size, Composition, and Multiple Sonication Points on Sterile Inflammatory Response in Focused Ultrasound-Mediated Blood–Brain Barrier Opening
ACS Biomaterials Science & Engineering · 09.12.2024 · 10 (12) · 7451-7465
DOI: 10.1021/acsbiomaterials.4c00777 ↗Kurz gefasst
Fachartikel in der Zeitschrift ACS Biomaterials Science & Engineering, online erschienen am 05.11.2024. Verfasst von Payton J Martinez und 6 weiteren Autor:innen. Beteiligte Einrichtung: Biomedical Engineering Program, University of Colorado Boulder, Boulder, Colorado 80303, United States. Hauptthemen laut MEDLINE: Microbubbles, Blood-Brain Barrier, Sonication. Die Arbeit wurde bisher 17-mal zitiert (Crossref) und nennt 65 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NCI NIH HHS, National Cancer Institute, Division of Graduate Education.
Abstract (Originalsprache)
Blood-brain barrier opening (BBBO) using focused ultrasound (FUS) and microbubbles (MBs) has emerged as a promising technique for delivering therapeutics to the brain. However, the influence of various FUS and MB parameters on BBBO and subsequent sterile inflammatory response (SIR) remains unclear. In this study, we investigated the effects of MB size and composition, as well as the number of FUS sonication points, on BBBO and SIR in an immunocompetent mouse model. Using MRI-guided MB + FUS, we targeted the striatum and assessed extravasation of an MRI contrast agent to assess BBBO and RNaseq to assess SIR. Our results revealed distinct effects of these parameters on BBBO and SIR. Specifically, at a matched microbubble volume dose (MVD), MB size did not affect the extent of BBBO, but smaller (1 μm diameter) MBs exhibited a lower classification of SIR than larger (3 or 5 μm diameter) MBs. Lipid-shelled microbubbles exhibited greater BBBO and a more pronounced SIR compared to albumin-shelled microbubbles, likely owing to the latter's poor in vivo stability. As expected, increasing the number of sonication points resulted in greater BBBO and SIR. Furthermore, correlation analysis revealed strong associations between passive cavitation detection measurements of harmonic and inertial MB echoes, BBBO, and the expression of SIR gene sets. Our findings highlight the critical role of MB and FUS parameters in modulating BBBO and subsequent SIR in the brain. These insights inform the development of targeted drug delivery strategies and the mitigation of adverse inflammatory reactions in neurological disorders.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Biomedical Engineering Program, University of Colorado Boulder, Boulder, Colorado 80303, United States.
- Morgan Adams Foundation Pediatric Brain Tumor Research Program, Department of Pediatrics, University of Colorado School of Medicine, Aurora, Colorado 80045, United States.
- Department of Mechanical Engineering, University of Colorado Boulder, Boulder, Colorado 80303, United States.
ORCID-Profile: Payton J Martinez, Jair I Castillo, Mark Borden
Förderung
- NCI NIH HHS
- National Cancer Institute
- Division of Graduate Education
Zitieren
APA
Martinez, P. J., Song, J. J., Castillo, J. I., DeSisto, J., Song, K. H., Green, A. L., & Borden, M. (2024). Effect of Microbubble Size, Composition, and Multiple Sonication Points on Sterile Inflammatory Response in Focused Ultrasound-Mediated Blood–Brain Barrier Opening. ACS Biomaterials Science & Engineering, 10(12), 7451-7465. https://doi.org/10.1021/acsbiomaterials.4c00777
Vancouver
Martinez PJ, Song JJ, Castillo JI, DeSisto J, Song KH, Green AL, et al. Effect of Microbubble Size, Composition, and Multiple Sonication Points on Sterile Inflammatory Response in Focused Ultrasound-Mediated Blood–Brain Barrier Opening. ACS Biomaterials Science & Engineering. 2024;10(12):7451-7465. doi:10.1021/acsbiomaterials.4c00777
BibTeX
@article{Martinez2024,
author = {Martinez, Payton J and Song, Jane J and Castillo, Jair I and DeSisto, John and Song, Kang-Ho and Green, Adam L and Borden, Mark},
title = {Effect of Microbubble Size, Composition, and Multiple Sonication Points on Sterile Inflammatory Response in Focused Ultrasound-Mediated Blood–Brain Barrier Opening},
journal = {ACS Biomaterials Science & Engineering},
year = {2024},
volume = {10},
number = {12},
pages = {7451--7465},
doi = {10.1021/acsbiomaterials.4c00777}
}
EUVIMED