EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Internal Fit of Cobalt–Chromium Metal–Ceramic Crowns Fabricated by Conventional Casting and Selective Laser Sintering: An In Vitro Comparison of Three Measurement Techniques

Daniela-Maria Pop, Lucian Floare, Delia Abrudan-Luca, Vlad Tiberiu Alexa, Tareq Hajaj, Boris Dusan Caplar, Lavinia Simona Florea, Cristian Zaharia, Doina Chioran

Medicine in Evolution · 15.12.2025 · 31 (4) · 437-447

DOI: 10.70921/medev.v31i4.2019 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Medicine in Evolution, online erschienen am 15.12.2025. Verfasst von Daniela-Maria Pop und 8 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

1.Background/Objectives: The purpose of this study was to compare the internal fit of cobalt-chromium metal-ceramic single crowns fabricated through conventional casting versus selective laser sintering (SLS), and to determinate the relative accuracy of three internal space measurement techniques. 2.

Methods

A standardized CAD design of a maxillary first molar was used to create two metal frameworks, one produced by was-pattern milling followed by casting and the other by SLS. Internal fit was assessed before and after ceramic firing using methods: differential micrometer measurements on frameworks with and without impression material, direct micrometer readings of detached silicons replicas, and digital microscopy of sectioned silicone specimens. 3.

Results

All methods revealed measurable differences in internal adaptation between the cast and SLS crown. Digital microscopy offered the highest precision and consistency, while micrometer-based techniques showed greater operator- dependent variability and were influenced by the elastic behaviour of the silicone impression material. Ceramic firing did not introduce clinically relevant changes in internal space. 4.

Conclusions

Within the limitation of the study, conventionally cast frameworks demonstrated a more favourable internal fit than SLS frameworks, and digital microscopy proved to be the most reliable method for evaluating internal adaptation in metal-ceramic crowns.

Zitieren

APA

Pop, D., Floare, L., Abrudan-Luca, D., Alexa, V. T., Hajaj, T., Caplar, B. D., Florea, L. S., Zaharia, C., & Chioran, D. (2025). Internal Fit of Cobalt–Chromium Metal–Ceramic Crowns Fabricated by Conventional Casting and Selective Laser Sintering: An In Vitro Comparison of Three Measurement Techniques. Medicine in Evolution, 31(4), 437-447. https://doi.org/10.70921/medev.v31i4.2019

Vancouver

Pop D, Floare L, Abrudan-Luca D, Alexa VT, Hajaj T, Caplar BD, et al. Internal Fit of Cobalt–Chromium Metal–Ceramic Crowns Fabricated by Conventional Casting and Selective Laser Sintering: An In Vitro Comparison of Three Measurement Techniques. Medicine in Evolution. 2025;31(4):437-447. doi:10.70921/medev.v31i4.2019

BibTeX
@article{Pop2025,
  author = {Pop, Daniela-Maria and Floare, Lucian and Abrudan-Luca, Delia and Alexa, Vlad Tiberiu and Hajaj, Tareq and Caplar, Boris Dusan and Florea, Lavinia Simona and Zaharia, Cristian and Chioran, Doina},
  title = {Internal Fit of Cobalt–Chromium Metal–Ceramic Crowns Fabricated by Conventional Casting and Selective Laser Sintering: An In Vitro Comparison of Three Measurement Techniques},
  journal = {Medicine in Evolution},
  year = {2025},
  volume = {31},
  number = {4},
  pages = {437--447},
  doi = {10.70921/medev.v31i4.2019}
}
Kostenlos starten →