EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Diagnostic Accuracy of Ultrasound for Prenatal Diagnosis of Placenta Accreta Compared with Magnetic Resonance Imaging

Syeda Maryam Tirmizi, Muhammad Nafees, Khashia Mamoon, Aamna Javaid

Indus Journal of Bioscience Research · 28.02.2025 · 3 (2) · 863-867

DOI: 10.70749/ijbr.v3i2.2896 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Indus Journal of Bioscience Research, online erschienen am 28.02.2025. Verfasst von Syeda Maryam Tirmizi und 3 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Placenta accreta spectrum disorders are linked to high maternal morbidity and, therefore, accurate prenatal diagnosis is essential to plan surgery on a timely basis and improve clinical outcomes. The aim of the study was to compare diagnostic performance of prenatal ultrasonography with MRI in diagnosing placenta accreta, and to determine the level of inter-modality agreement using intraoperative surgical findings as the final reference standard. Material and Methods: This research was conducted at radiology department of PAF Hospital, Islamabad from 15 August 2023 to 15 August 2024. We enrolled 92 high risk pregnant women. All the study subject underwent prenatal USG and subsequently MRI. Placenta accreta was defined based on predetermined imaging criteria, whereas the intraoperative findings of surgical findings acted as the gold standard. The diagnostic capability of the two modalities was compared through sensitivity, specificity, and positive predictive value (PPV), negative predictive value (NPV), and general accuracy. Cohen kappa was used to measure inter-modality agreement and stratified analyses were done to assess the effect of demographic and clinical variables.

Results

Placenta accreta was confirmed surgically in 39.1% of cases. Ultrasound demonstrated a sensitivity of 58.3%, specificity of 78.6%, and overall accuracy of 70.7%, while MRI showed higher sensitivity (72.2%), specificity (76.8%), and overall accuracy (75.0%). Intermodality agreement between ultrasound and MRI was moderate (κ = 0.50, p < 0.001). Stratified analysis revealed improved diagnostic performance in women with gestational age >31 weeks and age >29 years, with MRI showing more consistent accuracy across all subgroups.

Conclusion

MRI showed superior and consistent diagnostic sensitivity as compared to ultrasound and moderate concordance between the two modalities. The selective multimodal imaging approach can improve the diagnostic confidence in the high-risk pregnancies.

Zitieren

APA

Tirmizi, S. M., Nafees, M., Mamoon, K., & Javaid, A. (2025). Diagnostic Accuracy of Ultrasound for Prenatal Diagnosis of Placenta Accreta Compared with Magnetic Resonance Imaging. Indus Journal of Bioscience Research, 3(2), 863-867. https://doi.org/10.70749/ijbr.v3i2.2896

Vancouver

Tirmizi SM, Nafees M, Mamoon K, Javaid A. Diagnostic Accuracy of Ultrasound for Prenatal Diagnosis of Placenta Accreta Compared with Magnetic Resonance Imaging. Indus Journal of Bioscience Research. 2025;3(2):863-867. doi:10.70749/ijbr.v3i2.2896

BibTeX
@article{Tirmizi2025,
  author = {Tirmizi, Syeda Maryam and Nafees, Muhammad and Mamoon, Khashia and Javaid, Aamna},
  title = {Diagnostic Accuracy of Ultrasound for Prenatal Diagnosis of Placenta Accreta Compared with Magnetic Resonance Imaging},
  journal = {Indus Journal of Bioscience Research},
  year = {2025},
  volume = {3},
  number = {2},
  pages = {863--867},
  doi = {10.70749/ijbr.v3i2.2896}
}
Kostenlos starten →