Diagnostic Accuracy of Ultrasound in Placenta Accreta Spectrum Disorders
Pakistan Journal of Medical and Health Sciences · 21.01.2023 · 16 (12) · 947-952
DOI: 10.53350/pjmhs221612947 ↗Kurz gefasst
Fachartikel in der Zeitschrift Pakistan Journal of Medical and Health Sciences, online erschienen am 21.01.2023. Verfasst von Tabassum Begum und 5 weiteren Autor:innen.
Abstract (Originalsprache)
Objective
To determine the diagnostic accuracy of ultrasound in detecting placenta accreta spectrum disorders by using operative and histopathological findings as the reference standard. Material and Methods: This prospective diagnostic accuracy study was conducted at Mardan Medical Complex Mardan from 23 January 2022 to 23 September 2022. A total of 130 pregnant women with clinical risk factors or ultrasound suspicion of placenta accreta spectrum were enrolled through consecutive sampling. Targeted transabdominal ultrasound with color Doppler assessment was performed. Transvaginal ultrasound was added when required. Placental lacunae loss of the retroplacental clear zone myometrial thinning placental bulging bridging vessels and abnormal uterovesical vascularity were assessed. Ultrasound findings were compared with operative and histopathological diagnoses. Sensitivity specificity predictive values and overall accuracy were calculated.
Results
Placenta accreta spectrum was confirmed in 58 of 130 patients. Ultrasound correctly identified 54 affected patients and correctly excluded the disorder in 65 unaffected patients. Four false negative and seven false positive results were recorded. Sensitivity was 93.1 percent and specificity was 90.3 percent. Positive predictive value was 88.5 percent while negative predictive value was 94.2 percent. Overall diagnostic accuracy was 91.5 percent. Placental lacunae loss of the retroplacental clear zone myometrial thinning and increased subplacental vascularity were significantly associated with confirmed disease.
Conclusion
Ultrasound demonstrated high diagnostic accuracy for antenatal detection of placenta accreta spectrum disorders. Combined grayscale and color Doppler assessment was effective for identifying affected women and supporting planned obstetric management. Keywords: Placenta Accreta, Ultrasonography, Prenatal Diagnosis, Placenta Previa, Pregnancy Complications, Diagnostic Imaging
Zitieren
APA
Begum, T., Gul, H., Orakzai, Z. J., Khan, L., Baig, H., & Sadiq, M. (2023). Diagnostic Accuracy of Ultrasound in Placenta Accreta Spectrum Disorders. Pakistan Journal of Medical and Health Sciences, 16(12), 947-952. https://doi.org/10.53350/pjmhs221612947
Vancouver
Begum T, Gul H, Orakzai ZJ, Khan L, Baig H, Sadiq M. Diagnostic Accuracy of Ultrasound in Placenta Accreta Spectrum Disorders. Pakistan Journal of Medical and Health Sciences. 2023;16(12):947-952. doi:10.53350/pjmhs221612947
BibTeX
@article{Begum2023,
author = {Begum, Tabassum and Gul, Hemasa and Orakzai, Zubair Janan and Khan, Laila and Baig, Hina and Sadiq, Muhammad},
title = {Diagnostic Accuracy of Ultrasound in Placenta Accreta Spectrum Disorders},
journal = {Pakistan Journal of Medical and Health Sciences},
year = {2023},
volume = {16},
number = {12},
pages = {947--952},
doi = {10.53350/pjmhs221612947}
}
EUVIMED