Thermal-optical coupling and germicidal assessment of in-duct UV-C systems
Journal of Building Design and Environment · 2026
DOI: 10.70401/jbde.2026.0043 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Building Design and Environment, 2026. Verfasst von Sivamoorthy Kanagalingam und 6 weiteren Autor:innen.
Abstract (Originalsprache)
Ultraviolet germicidal irradiation (UVGI) is widely applied in heating, ventilation, and air-conditioning systems to reduce airborne pathogen transmission, yet its effectiveness depends on airflow-driven changes in lamp thermal condition and particle residence time. This study experimentally characterises the coupled thermal and optical performance of 95 W and 60 W low-pressure mercury ultraviolet-C (UV-C) lamps and uses the measured irradiance fields for comparative germicidal assessment. Air velocities of 1.1-2.5 m/s and ambient temperatures of 14-22 °C were varied to quantify their effects on lamp-surface temperature and 254 nm output. The 95 W lamp maintained near-maximum output over a broader operating range, whereas the 60 W lamp was more sensitive to convective cooling. Reynolds and Rayleigh numbers ranged from approximately 1.24 × 103 to 2.88 × 103 and 7.2 × 103 to 1.3 × 104, respectively, while the convection-to-radiation heat-loss ratio increased with airflow velocity. Mean modelled ultraviolet (UV) dose increased with lamp count and decreased with airflow velocity. At 1.1 m/s, six-lamp arrays delivered mean modelled doses of approximately 191 J/m2 for the 95 W lamps and 146 J/m2 for the 60 W lamps. Published UV susceptibility constants produced calculated reductions exceeding 6 log for susceptible viral and bacterial species, whereas the calculated reductions for Aspergillus spores ranged from below 0.05 to approximately 0.4 log. These microbial reductions were calculated from the measured irradiance fields and published susceptibility constants and were not experimentally validated using bioaerosols. The results provide a measurement-informed basis for comparing lamp power, airflow condition, and lamp arrangement in in-duct UVGI systems.
Zitieren
APA
Kanagalingam, S., An, H., Fong, Y. M., Soh, C. B., Chien, S., Wang, P. C., & Yu, S. C. M. (2026). Thermal-optical coupling and germicidal assessment of in-duct UV-C systems. Journal of Building Design and Environment. https://doi.org/10.70401/jbde.2026.0043
Vancouver
Kanagalingam S, An H, Fong YM, Soh CB, Chien S, Wang PC, et al. Thermal-optical coupling and germicidal assessment of in-duct UV-C systems. Journal of Building Design and Environment. 2026. doi:10.70401/jbde.2026.0043
BibTeX
@article{Kanagalingam2026,
author = {Kanagalingam, Sivamoorthy and An, Hui and Fong, Yin Mei and Soh, Chew Beng and Chien, Szu-Cheng and Wang, Peng Cheng and Yu, Simon Ching Man},
title = {Thermal-optical coupling and germicidal assessment of in-duct UV-C systems},
journal = {Journal of Building Design and Environment},
year = {2026},
doi = {10.70401/jbde.2026.0043}
}
EUVIMED