Simulation-Based Implementation of Germicidal UV-C Light Within a GMP Setting

Mahmoud Tawfieq, Nicolaj Stelzner Grønvall, Britt Rasmussen, Line Thaulov Østergaard

Hygiene · 31.10.2026 · 6 (4) · 77

DOI: 10.3390/hygiene6040077 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Hygiene, online erschienen am 31.10.2026. Verfasst von Mahmoud Tawfieq und 3 weiteren Autor:innen. Die Arbeit nennt 49 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Germicidal UV-C light has been around for 120 years, and while it is widely utilized in the food industry, it is less implemented within the pharmaceutical industry. In this paper, we present an optical-assisted implementation process of UV-C lamps within a Good Manufacturing Practice (GMP) setting. The presented approach consists of six steps: understanding the room; optical simulations; dose, cycle and frequency; safety; maintenance plan; and installation, verification and results. Each of these steps is described by following an actual implementation example inside a class D/C Personal Airlock (PAL). The Environmental Monitoring (EM) effect is compared 12 months prior to and 12 months after the implementation of the UV-C lamps. Here, it is shown that the total number of alerts was reduced from 32 (6.0%) to 12 (2.6%), the three-in-a-row alerts were reduced from 3 to 0, while the action levels were reduced from 4 (0.8%) to 0 (0.0%). The mean Colony-Forming Unit (CFU) count decreased from 3.60 before UV-C implementation to 1.94 after implementation, corresponding to a 46% reduction. Finally, we discuss different approaches of implementation into other types of cleanrooms, and possible mitigation actions should a UV-C system underperform.

Zitieren

APA

Tawfieq, M., Grønvall, N. S., Rasmussen, B., & Østergaard, L. T. (2026). Simulation-Based Implementation of Germicidal UV-C Light Within a GMP Setting. Hygiene, 6(4), 77. https://doi.org/10.3390/hygiene6040077

Vancouver

Tawfieq M, Grønvall NS, Rasmussen B, Østergaard LT. Simulation-Based Implementation of Germicidal UV-C Light Within a GMP Setting. Hygiene. 2026;6(4):77. doi:10.3390/hygiene6040077

BibTeX
@article{Tawfieq2026,
  author = {Tawfieq, Mahmoud and Grønvall, Nicolaj Stelzner and Rasmussen, Britt and Østergaard, Line Thaulov},
  title = {Simulation-Based Implementation of Germicidal UV-C Light Within a GMP Setting},
  journal = {Hygiene},
  year = {2026},
  volume = {6},
  number = {4},
  pages = {77},
  doi = {10.3390/hygiene6040077}
}