EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

GEOPHYSICAL INVESTIGATION AND SUBSURFACE HYDROGEOLOGICAL CHARACTERIZATION USING VERTICAL ELECTRICAL SOUNDING (VES) TECHNIQUE

ISHOLA, S. A.

Journal of Biodiversity and Environmental Research · 22.11.2026

DOI: 10.70382/sjber.v14i4.085 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Biodiversity and Environmental Research, online erschienen am 22.11.2026. Verfasst von ISHOLA und 1 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The significance geophysical investigation and subsurface hydrogeological characterization in determining the geoelectric layers and the corresponding variations of aquifer parameters, in estimating the depth to competent bedrock and aquifer units, delineating zones of leachate contamination and vulnerability to pollution cannot be overemphasized in environmental studies.This study was conducted around the Phase 1 of Apete-Akufo dumpsite environment, Ibadan, Southwestern Nigeria. The geophysical method adopted was Vertical Electrical Sounding (VES) using the Schlumberger electrode configuration across ten (10) VES stations with half-electrode spread length (AB/2) of 75m each. The acquired data were processed and interpreted Winresist software to delineate subsurface layers and evaluate groundwater-related parameters including aquifer thickness, overburden thickness, bedrock elevation and longitudinal conductance among others. The variations of the geoelectric parameters were carried on each location using both 2D/3D contouring technique with golden surfer software. The results revealed variations in the acquired geoelectric parameters across the study area. Topsoil resistivity ranged from 22.3 to 233.7Ωm, weathered-layer resistivity from 15.1 to 145.1Ωm, aquifer thickness from 3.2 to 29.0 m, and overburden thickness from 4.3 to 29.7m; consequently, delineating locations of comparably high and low groundwater yields and protections. Longitudinal conductance values range from 0.068 to 0.852 mhos, indicating poor to moderate protective capacity ranges from 10%, 20% and 70% respectively exhibiting poor, weak and moderate protective capacities with none exhibiting good to excellent protective capacities. These results suggest that groundwater protection varies across the study area, with 90% of the locations being more susceptible to contamination in varying proportions. The study confirms that VES is highly instrumental in evaluating subsurface conditions and groundwater vulnerability most particularly in a typical dumpsite environment. Areas with low protective capacity require greater attention because of their increased susceptibility to contaminant infiltration. Regular groundwater-quality monitoring and improved waste-management practices are therefore recommended to minimize leachate infiltration and protection of groundwater resources.

Zitieren

APA

ISHOLA, & A., S. (2026). GEOPHYSICAL INVESTIGATION AND SUBSURFACE HYDROGEOLOGICAL CHARACTERIZATION USING VERTICAL ELECTRICAL SOUNDING (VES) TECHNIQUE. Journal of Biodiversity and Environmental Research. https://doi.org/10.70382/sjber.v14i4.085

Vancouver

ISHOLA, A. S. GEOPHYSICAL INVESTIGATION AND SUBSURFACE HYDROGEOLOGICAL CHARACTERIZATION USING VERTICAL ELECTRICAL SOUNDING (VES) TECHNIQUE. Journal of Biodiversity and Environmental Research. 2026. doi:10.70382/sjber.v14i4.085

BibTeX
@article{ISHOLA2026,
  author = {ISHOLA and A., S.},
  title = {GEOPHYSICAL INVESTIGATION AND SUBSURFACE HYDROGEOLOGICAL CHARACTERIZATION USING VERTICAL ELECTRICAL SOUNDING (VES) TECHNIQUE},
  journal = {Journal of Biodiversity and Environmental Research},
  year = {2026},
  doi = {10.70382/sjber.v14i4.085}
}
Kostenlos starten →