Investigation Of Groundwater Pollution Around Angwan Gwandara Dumpsite, Garaku Vertical Electrical Sounding (VES)
Majmaah Journal of Health Sciences · 2026 · 14 (4) · 211
DOI: 10.5455/mjhs.2026.04.016 ↗Kurz gefasst
Fachartikel in der Zeitschrift Majmaah Journal of Health Sciences, 2026. Verfasst von Abubakar Madaki und 4 weiteren Autor:innen.
Abstract (Originalsprache)
Background and aim: Groundwater resources in rapidly urbanizing areas are increasingly threatened by improper waste disposal. This study assessed groundwater contamination around the Angwan Gwandara dumpsite in Garaku, Kokona Local Government Area, Nasarawa State, Nigeria. The aim was to evaluate subsurface resistivity variations, identify aquifer systems, and determine contamination risks.
Methods
Vertical Electrical Sounding surveys were conducted using Schlumberger and Wenner electrode configurations. Resistivity data were processed with IPI2WIN inversion software to delineate subsurface lithology and aquifer zones. Groundwater samples were collected from seven sources located 0.5–2 km from the dumpsite during the dry season. Samples were analyzed for physicochemical parameters (pH, electrical conductivity, turbidity, chloride, nitrate, sodium, calcium, and selected heavy metals) using standard hydrochemical techniques.
Results
Geophysical interpretation revealed three to five subsurface layers dominated by weathered and fractured basement formations that serve as the main aquifers. Some zones exhibited low resistivity values (10–100 Ωm), suggesting saturated and potentially contaminated formations. Hydrochemical results showed pH values ranging from 6.06 to 7.25, generally within permissible limits. However, electrical conductivity values (240–3500 µS/cm) exceeded recommended standards at several locations. Elevated nitrate, turbidity, and calcium levels were also observed, particularly in shallow wells located closer to the dumpsite.
Conclusion
Weathered and fractured basement formations facilitate contaminant migration, increasing the vulnerability of shallow aquifers to dumpsite leachate infiltration. Integrating electrical resistivity and hydrochemical analyses effectively identified groundwater contamination risks. Improved waste management practices, regular groundwater monitoring, and public health interventions are recommended to safeguard groundwater resources.
Zitieren
APA
Madaki, A., Maruku, M., Hamza, A., Ari, J., & Kazzayo, A. (2026). Investigation Of Groundwater Pollution Around Angwan Gwandara Dumpsite, Garaku Vertical Electrical Sounding (VES). Majmaah Journal of Health Sciences, 14(4), 211. https://doi.org/10.5455/mjhs.2026.04.016
Vancouver
Madaki A, Maruku M, Hamza A, Ari J, Kazzayo A. Investigation Of Groundwater Pollution Around Angwan Gwandara Dumpsite, Garaku Vertical Electrical Sounding (VES). Majmaah Journal of Health Sciences. 2026;14(4):211. doi:10.5455/mjhs.2026.04.016
BibTeX
@article{Madaki2026,
author = {Madaki, Abubakar and Maruku, Maruku and Hamza, Abdulkarim and Ari, Jamilu and Kazzayo, Ali},
title = {Investigation Of Groundwater Pollution Around Angwan Gwandara Dumpsite, Garaku Vertical Electrical Sounding (VES)},
journal = {Majmaah Journal of Health Sciences},
year = {2026},
volume = {14},
number = {4},
pages = {211},
doi = {10.5455/mjhs.2026.04.016}
}
EUVIMED