EUVIMEDEUVIMED entdecken
Crossref

Experimental Validation of a Self - Timed Active Common - Mode Voltage Clamp in a 1 kW Interleaved Dual - Buck Transformer - less PV Inverter

Dhananjay N., Bhagwan N., Umesh J., Vasant G., Arun V.

SciEngg Advances · 15.07.2026 · 03 (03) · 151

DOI: 10.69626/sea.2026.0151 ↗

Kurz gefasst

Fachartikel in der Zeitschrift SciEngg Advances, online erschienen am 15.07.2026. Verfasst von Dhananjay N. und 4 weiteren Autor:innen.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Removing the isolation transformer from a grid-connected photovoltaic (PV) inverter raises efficiency but leaves the parasitic capacitance of the array exposed to the common-mode voltage of the inverter. This paper reports the hardware validation of a 1 kW interleaved dual-buck full-bridge inverter with an active common-mode voltage clamp (IDBFB-ACMVC). Two 40 kHz buck legs interleaved by 180° shape a rectified sine, a 50 Hz insulated-gate bipolar transistor (IGBT) bridge unfolds it, and two anti-series MOSFETs with a 100 nF film capacitor join the buck output to the DC-link midpoint whenever neither buck switch is on. The clamp is switched by a NOR of the gate commands already generated for the two buck switches, so it uses no pulse-width modulation (PWM) channel of its own and carries no load current. The prototype was brought up in stages, from a perfboard unfolding bridge to a single printed circuit board with a dsPIC33 controller and gate drivers matched to the reference node and switching rate of each switch. From a 380 V DC bus, with a 100 nF capacitor emulating the array capacitance, the clamp reduces the measured leakage current from 46.4 mA to 9.6 mA RMS (79.3%), 3.1 times below the 30 mA threshold of VDE 0126-1-1. Efficiency peaks at 96.7% at 700 W and is 95.9% at 1 kW, voltage and current total harmonic distortion are 1.99% and 3.54%, and the power factor exceeds 0.99. Separating the measured leakage into its 100 Hz floor and its dead-time drift shows that the clamp removes about 81% of the drift.

Zitieren

APA

N., D., N., B., J., U., G., V., & V., A. (2026). Experimental Validation of a Self - Timed Active Common - Mode Voltage Clamp in a 1 kW Interleaved Dual - Buck Transformer - less PV Inverter. SciEngg Advances, 03(03), 151. https://doi.org/10.69626/sea.2026.0151

Vancouver

N. D, N. B, J. U, G. V, V. A. Experimental Validation of a Self - Timed Active Common - Mode Voltage Clamp in a 1 kW Interleaved Dual - Buck Transformer - less PV Inverter. SciEngg Advances. 2026;03(03):151. doi:10.69626/sea.2026.0151

BibTeX
@article{N2026,
  author = {N., Dhananjay and N., Bhagwan and J., Umesh and G., Vasant and V., Arun},
  title = {Experimental Validation of a Self - Timed Active Common - Mode Voltage Clamp in a 1 kW Interleaved Dual - Buck Transformer - less PV Inverter},
  journal = {SciEngg Advances},
  year = {2026},
  volume = {03},
  number = {03},
  pages = {151},
  doi = {10.69626/sea.2026.0151}
}