Design and Analysis of an Interleaved Dual - Buck Full - Bridge Transformerless Inverter with Active Common-Mode Voltage Clamp for Photovoltaic Applications

Dhananjay N., Bhagwan N., Prerna A., Anil G., V. G., Arun V.

SciEngg Advances · 02.07.2026 · 03 (03) · 123

DOI: 10.69626/sea.2026.0123 ↗

Kurz gefasst

Fachartikel in der Zeitschrift SciEngg Advances, online erschienen am 02.07.2026. Verfasst von Dhananjay N. und 5 weiteren Autor:innen.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Transformerless photovoltaic (PV) inverters have emerged as the preferred solution for grid-connected residential and commercial systems owing to their reduced size, lower cost, and improved efficiency achieved by eliminating the line-frequency transformer. However, the absence of galvanic isolation introduces common-mode (CM) leakage current through the parasitic capacitance between the PV array and the grounded module frame, leading to safety concerns, electromagnetic interference, and reduced system reliability. This paper presents the design and analysis of an interleaved dual-buck full-bridge (IDBFB) transformerless inverter incorporating an active common-mode voltage clamp (ACMVC) to mitigate residual CM voltage and suppress leakage current. The proposed topology employs two interleaved buck converters operating at 40 kHz for high-frequency power processing, while a 50 Hz unfolding full-bridge generates the grid-frequency AC output, thereby inherently reducing CM voltage variations. To eliminate the residual CM voltage generated during buck-converter dead-time intervals, an ACMVC comprising two back-to-back MOSFETs, a blocking capacitor, and a simple NOR-gate-based control circuit is introduced to clamp the buck-output node to the DC-link midpoint. A 1 kW, 230 V RMS, 50 Hz prototype system is designed and modelled in MATLAB/Simulink to evaluate the proposed control strategy. Simulation results verify correct PWM generation, interleaved converter operation, synchronized unfolding-bridge switching, and effective clamp activation during dead-time intervals, demonstrating the feasibility of the proposed approach for reducing common-mode disturbances. The presented work establishes a practical design framework for transformerless PV inverters and provides a foundation for future experimental validation of leakage current, total harmonic distortion, conversion efficiency, and compliance with grid-interconnection standards.

Zitieren

APA

N., D., N., B., A., P., G., A., G., V., & V., A. (2026). Design and Analysis of an Interleaved Dual - Buck Full - Bridge Transformerless Inverter with Active Common-Mode Voltage Clamp for Photovoltaic Applications. SciEngg Advances, 03(03), 123. https://doi.org/10.69626/sea.2026.0123

Vancouver

N. D, N. B, A. P, G. A, G. V, V. A. Design and Analysis of an Interleaved Dual - Buck Full - Bridge Transformerless Inverter with Active Common-Mode Voltage Clamp for Photovoltaic Applications. SciEngg Advances. 2026;03(03):123. doi:10.69626/sea.2026.0123

BibTeX
@article{N2026,
  author = {N., Dhananjay and N., Bhagwan and A., Prerna and G., Anil and G., V. and V., Arun},
  title = {Design and Analysis of an Interleaved Dual - Buck Full - Bridge Transformerless Inverter with Active Common-Mode Voltage Clamp for Photovoltaic Applications},
  journal = {SciEngg Advances},
  year = {2026},
  volume = {03},
  number = {03},
  pages = {123},
  doi = {10.69626/sea.2026.0123}
}
Kostenlos starten →