Empirical Analysis of Pressure Drop in Different Types of Fittings: A Case Study with AFT/FME00

ZABDAMIR MIRZADA, ASRARUDDIN GULZAD

Kabul Polytechnic University International Journal of Engineering & Technology · 07.11.2026 · 6 (2) · 1-20

DOI: 10.68924/b6c0v440 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Kabul Polytechnic University International Journal of Engineering & Technology, online erschienen am 07.11.2026. Verfasst von ZABDAMIR MIRZADA und 1 weiteren Autor:innen.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Local resistance in hydraulic systems is one of the important design and application parameters that has a direct effect on the operation and energy consumption of pumps. In this study, pressure drop in six types of local resistance including filter, T-connection, 90-degree knee bend, two consecutive 90-degree knee bend, 45-degree knee bend and parallel pipe system were experimentally investigated using AFT/FME00 laboratory device manufactured by Edibon Company in the Laboratory of Chemical Engineering, Kabul Polytechnic University. The research was carried out using water as a fluid in the work area and at a flow of about 600 to 2400 liters per hour. For each flow size, pressure drop, flow velocity, Reynolds number and local pressure drop coefficient (ζ) were calculated. The Reynolds number in this study was between 11,253 and 45,015, which indicates the turbulent flow in the experiments, and the results showed that the ratio filter produces the greatest pressure drop. During 2400 liters per hour, its pressure dropped reached 19999.94 Pascals, and its average pressure drop coefficient was about ζ = 9.50. In contrast, the kneecap of 45 degrees showed the lowest pressure drop, varying from 49.05 to 568.98 Pascals, and its average pressure drop coefficient was about ζ = 0.267. The results also showed that with increasing the size of the flow, the pressure drop increases significantly, and in irregular flow conditions, the pressure drop coefficient tends to decrease with increasing the Reynolds number. These results show the necessity and importance of proper selection of fittings in the design of hydraulic systems to reduce energy loss and improve system performance.

Zitieren

APA

MIRZADA, Z., & GULZAD, A. (2026). Empirical Analysis of Pressure Drop in Different Types of Fittings: A Case Study with AFT/FME00. Kabul Polytechnic University International Journal of Engineering & Technology, 6(2), 1-20. https://doi.org/10.68924/b6c0v440

Vancouver

MIRZADA Z, GULZAD A. Empirical Analysis of Pressure Drop in Different Types of Fittings: A Case Study with AFT/FME00. Kabul Polytechnic University International Journal of Engineering & Technology. 2026;6(2):1-20. doi:10.68924/b6c0v440

BibTeX
@article{MIRZADA2026,
  author = {MIRZADA, ZABDAMIR and GULZAD, ASRARUDDIN},
  title = {Empirical Analysis of Pressure Drop in Different Types of Fittings: A Case Study with AFT/FME00},
  journal = {Kabul Polytechnic University International Journal of Engineering & Technology},
  year = {2026},
  volume = {6},
  number = {2},
  pages = {1--20},
  doi = {10.68924/b6c0v440}
}