Agreement Between Different Types of Blood Pressure Monitoring
Annals of Internal Medicine · 2025-10 · 178 (10) · 1441-1450
DOI: 10.7326/annals-24-02142 ↗Kurz gefasst
Netzwerk-Metaanalyse in der Zeitschrift Annals of Internal Medicine, 2025-10. Verfasst von Jiunn-Tyng Yeh und 10 weiteren Autor:innen. Beteiligte Einrichtung: Department of Medical Education, Taipei Veterans General Hospital, and Department of Medicine, National Yang Ming Chiao Tung University College of Me…. Hauptthemen laut MEDLINE: Blood Pressure Determination, Blood Pressure Monitoring, Ambulatory, Hypertension. Die Arbeit wurde bisher 9-mal zitiert (Crossref) und nennt 31 Literaturangaben.
Abstract (Originalsprache)
BACKGROUND: Accurate blood pressure measurement (BPM) is essential for managing hypertension, but previous studies have not systematically compared different monitoring methods across varying BP levels. To address this gap, a comprehensive analysis using network meta-analysis (NMA) and meta-regression was done to evaluate their agreement and clinical implications. PURPOSE: To compare BP values obtained using different BPM methods using office BPM (OBPM) as the reference. DATA SOURCES: Studies published in MEDLINE and Scopus up to October 2024. STUDY SELECTION: Studies aimed to compare the values between BPM methods in participants older than 18 years. DATA EXTRACTION: Risk of bias was assessed on the basis of the internal validity of the study overall and the quality of the BPM methods. The mean differences between BPMs were calculated using NMA and meta-regression. DATA SYNTHESIS: Sixty-five studies encompassing 40 022 participants were analyzed. Compared with research office systolic BPM, the pooled mean differences from corresponding systolic BPs were 2.69 mm Hg (95% CI, -0.13 to 5.51 mm Hg) higher for convenient OBPM, 4.57 mm Hg (CI, 2.54 to 6.60 mm Hg) lower for automated OBPM, 4.59 mm Hg (CI, 2.83 to 6.34 mm Hg) lower for home BPM, 4.22 mm Hg (CI, 2.62 to 5.82 mm Hg) lower for daytime ambulatory BPM (ABPM), 18.14 mm Hg (CI, 16.21 to 20.06 mm Hg) lower for nighttime ABPM, and 8.63 mm Hg (CI, 6.97 to 10.28 mm Hg) lower for 24-hour ABPM. Differences varied by reference research OBPM levels: Higher reference BP levels are associated with larger differences between research office and other BPM methods. LIMITATION: Heterogeneity due to the inclusion of studies with different research designs. CONCLUSION: Our analysis found differences among BPM methods that varied from the recommendations of current hypertension guidelines. Furthermore, discrepancies were more pronounced at elevated BP levels. PRIMARY FUNDING SOURCE: Ministry of Health and Welfare, Taiwan. (PROSPERO: CRD42021246448).
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Department of Medical Education, Taipei Veterans General Hospital, and Department of Medicine, National Yang Ming Chiao Tung University College of Medicine, Taipei, Taiwan (J.-T.Y.).
- Division of Evidence-based Medicine, Taipei Veterans General Hospital, Taipei, Taiwan (C.-J.H.).
- Institute of Public Health and Community Medicine Research Center, National Yang Ming Chiao Tung University College of Medicine, Taipei, Cardiovascular Division, Department of Internal Medicine, MacKay Memorial Hospital…
- Division of Cardiovascular Medicine, Department of Internal Medicine, Wan Fang Hospital, Taipei Medical University, Taipei, Division of Cardiology, Department of Internal Medicine, School of Medicine, College of Medicin…
- Department of Medical Education, Taipei Veterans General Hospital, Taipei, Taiwan (S.-L.H., T.-J.C.).
- Division of Cardiology, Department of Internal Medicine, Taipei Veterans General Hospital, and Department of Medicine, National Yang Ming Chiao Tung University College of Medicine, Taipei, Taiwan (W.-T.W.).
ORCID-Profile: Jiunn-Tyng Yeh, Yu-Jen Chen, Wei-Ting Wang, Yu-Kang Tu, Hao-Min Cheng
Zitieren
APA
Yeh, J. T., Huang, C. J., Lee, C. W., Chen, Y. J., Huang, S. L., Wang, W. T., Tu, Y. K., Chiu, T. J., Chiang, C. E., Chen, C. H., & Cheng, H. M. (2025). Agreement Between Different Types of Blood Pressure Monitoring. Annals of Internal Medicine, 178(10), 1441-1450. https://doi.org/10.7326/annals-24-02142
Vancouver
Yeh JT, Huang CJ, Lee CW, Chen YJ, Huang SL, Wang WT, et al. Agreement Between Different Types of Blood Pressure Monitoring. Annals of Internal Medicine. 2025;178(10):1441-1450. doi:10.7326/annals-24-02142
BibTeX
@article{Yeh2025,
author = {Yeh, Jiunn-Tyng and Huang, Chi-Jung and Lee, Chun-Wei and Chen, Yu-Jen and Huang, Shao-Li and Wang, Wei-Ting and Tu, Yu-Kang and Chiu, Tzu-Jung and Chiang, Chern-En and Chen, Chen-Huan and Cheng, Hao-Min},
title = {Agreement Between Different Types of Blood Pressure Monitoring},
journal = {Annals of Internal Medicine},
year = {2025},
volume = {178},
number = {10},
pages = {1441--1450},
doi = {10.7326/annals-24-02142}
}
EUVIMED