EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Quantitative Fit-Testing of N95 Respirators: Part I—Method Development

Ziqing Zhuang, C.C. Coffey, W.R. Myers, J. Yang, D.L. Campbell

Journal of the International Society for Respiratory Protection · 1998

DOI: 10.66828/001c.168222 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of the International Society for Respiratory Protection, 1998. Verfasst von Ziqing Zhuang und 4 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This is the first of two articles dealing with quantitative fit-testing of N95 filtering- facepiece respirators (a new class of particulate respirators in the United States). The purpose of this study was to develop a protocol for using the TSI, Inc. PortaCount Plus™ to quantitatively fit test N95 respirators. The development of the protocol consisted of four parts: 1) designing a clamp so that the PortaCount Plus™ could be used to measure the penetration of ambient aerosol through N95 filters; 2) determining the magnitude of the ambient aerosol penetration; 3) comparing different filter penetration methods, i.e., the PortaCount Plus™, a laboratory condensation nuclei counter (lab CNC), and the sodium chloride (NaCl) filter efficiency level test; and 4) determining the effect of testing position on ambient aerosol filter penetration. Ambient aerosol filter penetration was measured with the PortaCount Plus™ and clamps designed in such a way that a small area of the filter was sealed so that the filter penetration of ambient aerosol through this sealed area was measured and used to estimate the penetration through the respirator when a wearer breathes. One-sided t-tests showed that filter penetration measured with the PortaCount Plus™ and a clamp was significantly greater than 0.03% (a = 0.05). To investigate the effect of filter penetration testing position, ambient aerosol filter penetration was measured with a clamp at 10 testing positions on five different respirators of the same model. Ambient aerosol filter penetration was found to be affected by the placement of the clamp on the respirator. It was also found that the NaCl test provided filter penetrations that were significantly higher than those measured with the PortaCount Plus™ and lab CNC (a = 0.05). To fit test N95 respirators using ambient aerosol, the filter penetration needed to be subtracted from the total inward leakage to obtain faceseal leakage. Finally, a protocol was developed to fit test N95 respirators, use the PortaCount Plus™ and the clamp to measure filter penetration, and adjust the measured fit factor for filter penetration. Part n gives the results of quantitatively fit-testing 21N95 respirators using this protocol.

Zitieren

APA

Zhuang, Z., Coffey, C., Myers, W., Yang, J., & Campbell, D. (1998). Quantitative Fit-Testing of N95 Respirators: Part I—Method Development. Journal of the International Society for Respiratory Protection. https://doi.org/10.66828/001c.168222

Vancouver

Zhuang Z, Coffey C, Myers W, Yang J, Campbell D. Quantitative Fit-Testing of N95 Respirators: Part I—Method Development. Journal of the International Society for Respiratory Protection. 1998. doi:10.66828/001c.168222

BibTeX
@article{Zhuang1998,
  author = {Zhuang, Ziqing and Coffey, C.C. and Myers, W.R. and Yang, J. and Campbell, D.L.},
  title = {Quantitative Fit-Testing of N95 Respirators: Part I—Method Development},
  journal = {Journal of the International Society for Respiratory Protection},
  year = {1998},
  doi = {10.66828/001c.168222}
}
Kostenlos starten →