EUVIMEDEUVIMED entdecken
Crossref

Standardless, Quantitative SIMS Using the Full Spectrum Method (FSM): Part I. Polymers

Nicolas Molina, John F Curry iD, Filippo Mangolini iD

Analytical Chemistry · 13.01.2026 · 98 (1) · 1005-1012

DOI: 10.1021/acs.analchem.5c06373 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Analytical Chemistry, online erschienen am 19.12.2025. Verfasst von Nicolas Molina und 2 weiteren Autor:innen. Beteiligte Einrichtung: Texas Materials Institute, The University of Texas at Austin, Austin, Texas 78712, United States. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 35 Literaturangaben. Gefördert von: Welch Foundation, Division of Civil, Mechanical and Manufacturing Innovation.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Time-of-flight secondary ion mass spectrometry (ToF-SIMS) is a powerful surface-analytical method extensively used in a variety of scientific fields and industrial sectors. However, quantitative ToF-SIMS analyses are challenging and limit the broader applicability of this characterization technique. This study demonstrates the use of the full spectrum method (FSM) as a quantitative technique for analyzing homopolymers (e.g., polypropylene (PP), polystyrene (PS), and polytetrafluoroethylene (PTFE)) using ToF-SIMS. By analyzing the entire collection of sputtered secondary ions, FSM minimizes "matrix effects" that commonly impede the quantitative ToF-SIMS analysis of polymers. The results indicate that the acquisition of ToF-SIMS data should be carried out while varying the primary ion fluence. This approach yields experimental data that can be directly compared with theoretical predictions of ion-induced surface damage, thus providing unambiguous evidence for the effect of ion bombardment and whether the quantification was performed with clusters whose intensity is affected by ion-induced damage. Overall, the outcomes of this work establish FSM as a powerful tool for multicomponent analysis, advancing the precise surface characterization of polymeric materials via ToF-SIMS.

Autor:innen und Institutionen

  • Texas Materials Institute, The University of Texas at Austin, Austin, Texas 78712, United States.
  • Materials Science and Engineering Program, The University of Texas at Austin, Austin, Texas 78712, United States.
  • Material, Physical, and Chemical Sciences Center, Sandia National Laboratories, Albuquerque, New Mexico 87185, United States.
  • Walker Department of Mechanical Engineering, The University of Texas at Austin, Austin, Texas 78712, United States.

ORCID-Profile: John F Curry, Filippo Mangolini

Förderung

  • Welch Foundation
  • Division of Civil, Mechanical and Manufacturing Innovation

Zitieren

APA

Molina, N., Curry, J. F., & Mangolini, F. (2026). Standardless, Quantitative SIMS Using the Full Spectrum Method (FSM): Part I. Polymers. Analytical Chemistry, 98(1), 1005-1012. https://doi.org/10.1021/acs.analchem.5c06373

Vancouver

Molina N, Curry JF, Mangolini F. Standardless, Quantitative SIMS Using the Full Spectrum Method (FSM): Part I. Polymers. Analytical Chemistry. 2026;98(1):1005-1012. doi:10.1021/acs.analchem.5c06373

BibTeX
@article{Molina2026,
  author = {Molina, Nicolas and Curry, John F and Mangolini, Filippo},
  title = {Standardless, Quantitative SIMS Using the Full Spectrum Method (FSM): Part I. Polymers},
  journal = {Analytical Chemistry},
  year = {2026},
  volume = {98},
  number = {1},
  pages = {1005--1012},
  doi = {10.1021/acs.analchem.5c06373}
}
Kostenlos starten →