Evaluation of a Shortened Fit Test Protocol for Elastomeric Half-Mask Respirators Using the OHD Quantifit®
Journal of the International Society for Respiratory Protection · 01.07.2022 · 39 (1)
DOI: 10.66828/001c.166378 ↗Kurz gefasst
Studienprotokoll in der Zeitschrift Journal of the International Society for Respiratory Protection, online erschienen am 01.07.2022. Verfasst von Leshan J. Kimbrough* und 2 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Annual fit testing, as mandated by the Occupational Safety and Health Administration (OSHA), is required for every employee in the United States who wears a tight-fitting respirator. Considering the volume of fit tests performed annually, a reduced test duration would prove advantageous. This study evaluated a shortened fit test protocol for elastomeric half-mask respirators using Controlled Negative Pressure (CNP) technology. The new protocol is a modification of the OSHA-accepted CNP REDON protocol and would reduce the test duration to 1.9 minutes. The overall fit factor measured using the new method was compared to that of a reference method following the “Criteria for Evaluating New Fit Test Methods” outlined in American National Standards Institute (ANSI) publication Z88.10-2010, Annex A2. Sequential paired fit tests were performed on human test participants during the same respirator donning. Fit factors were measured using the Quantifit® CNP instrument. The exercise set for the reference method was the standard OSHA 8-exercise protocol for CNP-based instruments. The exercise set for the modified-REDON method included facing forward, facing parallel to the floor, head shaking, and two redon exercises. The results demonstrated that the sensitivity of the shortened method (0.98) was greater than the requirement (>0.95) defined in ANSI Z88.10-2010. The new method also met the test specificity, predictive value of a pass, predictive value of a failure, and kappa statistic recommended by ANSI. This study also evaluated the effect of reducing the number of redon exercises from two to one, further decreasing the test duration to 1.2 minutes. The results demonstrated the sensitivity (0.98) remained unchanged indicating removal of the second redon step would not negatively impact the ability of the new method to effectively identify poorly fitting respirators.
Zitieren
APA
Kimbrough*, L. J., Duncan, R. C., & Dawson, O. R. (2022). Evaluation of a Shortened Fit Test Protocol for Elastomeric Half-Mask Respirators Using the OHD Quantifit®. Journal of the International Society for Respiratory Protection, 39(1). https://doi.org/10.66828/001c.166378
Vancouver
Kimbrough* LJ, Duncan RC, Dawson OR. Evaluation of a Shortened Fit Test Protocol for Elastomeric Half-Mask Respirators Using the OHD Quantifit®. Journal of the International Society for Respiratory Protection. 2022;39(1). doi:10.66828/001c.166378
BibTeX
@article{Kimbrough2022,
author = {Kimbrough*, Leshan J. and Duncan, Riley C. and Dawson, Olivia R.},
title = {Evaluation of a Shortened Fit Test Protocol for Elastomeric Half-Mask Respirators Using the OHD Quantifit®},
journal = {Journal of the International Society for Respiratory Protection},
year = {2022},
volume = {39},
number = {1},
doi = {10.66828/001c.166378}
}