Evaluation of a Shortened Fit Test Protocol for Full- Facepiece Respirators Using the OHD Quantifit®
Journal of the International Society for Respiratory Protection · 01.07.2023 · 40 (1)
DOI: 10.66828/001c.166371 ↗Kurz gefasst
Studienprotokoll in der Zeitschrift Journal of the International Society for Respiratory Protection, online erschienen am 01.07.2023. Verfasst von Leshan J. Kimbrough* und 3 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Annual fit testing, as mandated by the Occupational Safety and Health Administration (OSHA), is required for every employee in the United States who wears a tight-fitting respirator. Considering the volume of fit tests performed annually, a reduced test duration would prove advantageous. This study evaluated two shortened fit test protocols for full-facepiece respirators using Controlled Negative Pressure (CNP) technology. This study is a continuation of a previous study that evaluated the effectiveness and accuracy of the same shortened protocols for elastomeric half-mask respirators. The new protocols are a modification of the OSHA-accepted CNP REDON protocol, titled modified-REDON and brief-REDON, and would reduce the test duration to 1.9 and 1.2 minutes, respectively. The overall fit factor measured using the new methods was compared to that of a reference method following the “Criteria for Evaluating New Fit Test Methods” outlined in American National Standards Institute (ANSI) publication Z88.10-2010, Annex A2. Sequential paired fit tests were performed on human test participants during the same respirator donning. Fit factors were measured using the Quantifit® CNP instrument. The exercise set for the reference method was the standard OSHA 8-exercise protocol for CNP-based instruments. The exercise set for the modified-REDON method included facing forward, facing parallel to the floor, head shaking, and two redon exercises. The results demonstrated that the sensitivity of the modified-REDON method (1.00) was greater than the requirement (>0.95) defined in ANSI Z88.10-2010. The modified- REDON method also met the test specificity, predictive value of a pass, predictive value of a fail, and kappa statistic recommended by ANSI. The brief-REDON method evaluated the effect of reducing the number of redon exercises from two to one. The results demonstrated the sensitivity (0.99) remained essentially unchanged indicating removal of the second redon step would not negatively impact the ability of the new method to effectively identify poorly fitting respirators.
Zitieren
APA
Kimbrough*, L. J., Dawson, O. R., Stout, S. L., & Rollins, V. L. (2023). Evaluation of a Shortened Fit Test Protocol for Full- Facepiece Respirators Using the OHD Quantifit®. Journal of the International Society for Respiratory Protection, 40(1). https://doi.org/10.66828/001c.166371
Vancouver
Kimbrough* LJ, Dawson OR, Stout SL, Rollins VL. Evaluation of a Shortened Fit Test Protocol for Full- Facepiece Respirators Using the OHD Quantifit®. Journal of the International Society for Respiratory Protection. 2023;40(1). doi:10.66828/001c.166371
BibTeX
@article{Kimbrough2023,
author = {Kimbrough*, Leshan J. and Dawson, Olivia R. and Stout, Sabrina L. and Rollins, Victoria L.},
title = {Evaluation of a Shortened Fit Test Protocol for Full- Facepiece Respirators Using the OHD Quantifit®},
journal = {Journal of the International Society for Respiratory Protection},
year = {2023},
volume = {40},
number = {1},
doi = {10.66828/001c.166371}
}
EUVIMED