EUVIMEDDescoperă EUVIMED
Open access · CC BY 4.0

Enhanced Duration SCBA

Hans Almqvist

Journal of the International Society for Respiratory Protection · 2023-01-01 · 39 (2)

DOI: 10.66828/001c.166375 ↗

At a glance

Journal article in Journal of the International Society for Respiratory Protection, published online on 2023-01-01. Written by Hans Almqvist. The full text is freely available (open access, CC BY 4.0).

RezumatDate bibliograficeCiteRelated studies

Abstract (original language)

Background

The Open-Circuit Self Contained Breathing Apparatus (SCBA) has been used for almost a century in the fire service worldwide and contributed to keeping firefighters safe as well as enhancing their performance. Several improvements have been made over the years; however, the air flow pattern is still the same as it was one hundred years ago. All the exhaled air is vented to the surroundings, including the air that has not participated in the oxygen/carbon dioxide exchange in the lungs. It is the purpose of the presented concept to change the breathing pattern with the goal to make the SCBA more efficient.

Methods

With every breath we take, some of the exhaled air comes from the mouth and trachea and has not entered the lungs for the oxygen/carbon dioxide exchange and is consequently possible to rebreathe. If a breathing mask with valves is used, the amount of re-breathable air can be increased by the air contained in the nose cup and adjacent cavities in the end of the inhalation. In average, 0.4 -0.5 liter of air, which in current technology units is wasted, has full oxygen content and only insignificant amount of carbon dioxide and can be reused. By capturing the unused air in a reservoir in the beginning of the exhalation and re-using it for the next breath, the air consumption can be substantially reduced. By reusing the air as described and always keeping the gas concentrations within acceptable limits it is estimated that the Duration/Weight (D/W) ratio for a SCBA can be increased by 50-100%, compared to present technology, depending on the degree of electronics sophistication.

Results

A human pilot test with a laboratory prototype without any advanced electronics has been performed at Duke University, NC, USA, and an increase in D/W ratio of 30% was recorded, indicating that the concept has merits.

Conclusion

The actual working duration for current SCBA can vary enormously depending on the physiology of the wearer, the task being performed, and the operating environment. It is not uncommon for 30-minute rated sets to be exhausted in 15-20 minutes. The new technology can give the firefighter more duration and extra reserve in case of getting trapped or disorientated, without increased weight.

Cite

APA

Almqvist, H. (2023). Enhanced Duration SCBA. Journal of the International Society for Respiratory Protection, 39(2). https://doi.org/10.66828/001c.166375

Vancouver

Almqvist H. Enhanced Duration SCBA. Journal of the International Society for Respiratory Protection. 2023;39(2). doi:10.66828/001c.166375

BibTeX
@article{Almqvist2023,
  author = {Almqvist, Hans},
  title = {Enhanced Duration SCBA},
  journal = {Journal of the International Society for Respiratory Protection},
  year = {2023},
  volume = {39},
  number = {2},
  doi = {10.66828/001c.166375}
}
Start for free →