EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Fit Testing of Respirators With Ear Loop Straps

Nick Baxter*, Helen Beattie, Gillian Nicholls, Duncan Smith

Journal of the International Society for Respiratory Protection · 30.06.2024 · 41 (1)

DOI: 10.66828/001c.166356 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of the International Society for Respiratory Protection, online erschienen am 30.06.2024. Verfasst von Nick Baxter* und 3 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Due to large demand for respirators during the COVID-19 pandemic, particularly filtering facepiece respirators (FFP) level 3 (FFP3) in Great Britain (GB), an increasing number of FFPs with ear loop straps were imported into GB from outside of Europe. Many of these FFPs were incorrectly and often dually marked, showing a European “CE” (“Conformité Européenne”) mark which indicates conformance with the European standard BS EN 149 for respiratory protective devices (RPD), and a KN95 marking, which shows conformity to the Chinese standard GB 2626-2006 for respiratory protective equipment (RPE). There is evidence suggesting FFPs with ear loop straps do not pass a fit test on a significant proportion of the intended population, with many studies throughout the world demonstrating a low fit testing pass rate of FFPs with ear loop straps.

Objective

The aim of this study was to evaluate the fit of KN95 style respirators with ear loop straps on volunteers representative of GB users, using a quantitative fit testing method.

Methods

Eight models of respirators with ear loop straps, with no certification documentation, were selected from different manufacturers. Quantitative fit testing using an ambient particle counting method was conducted on 29 volunteers. The order of the fit testing on each respirator was randomised. The study followed the fit testing protocol as described in Health and Safety Executive (HSE) guidance on RPE fit testing, INDG 479.

Results

From the 232 fit tests completed, only one achieved a fit factor above the pass/fail criteria of 100. The data showed a 95% confidence that the geometric mean of the overall fit factors lies between 3.0 and 4.7, and is significantly lower (P

Zitieren

APA

Baxter*, N., Beattie, H., Nicholls, G., & Smith, D. (2024). Fit Testing of Respirators With Ear Loop Straps. Journal of the International Society for Respiratory Protection, 41(1). https://doi.org/10.66828/001c.166356

Vancouver

Baxter* N, Beattie H, Nicholls G, Smith D. Fit Testing of Respirators With Ear Loop Straps. Journal of the International Society for Respiratory Protection. 2024;41(1). doi:10.66828/001c.166356

BibTeX
@article{Baxter2024,
  author = {Baxter*, Nick and Beattie, Helen and Nicholls, Gillian and Smith, Duncan},
  title = {Fit Testing of Respirators With Ear Loop Straps},
  journal = {Journal of the International Society for Respiratory Protection},
  year = {2024},
  volume = {41},
  number = {1},
  doi = {10.66828/001c.166356}
}
Kostenlos starten →