Optimization of IVIM-Diffusion MRI protocol for Quantifying Pancreatic Perfusion between Free-breath and Respiratory triggering controls
Journal of Associated Medical Sciences · 12.11.2026 · 60 (1) · 268-281
DOI: 10.66285/jams.2027.025 ↗Kurz gefasst
Studienprotokoll in der Zeitschrift Journal of Associated Medical Sciences, online erschienen am 12.11.2026. Verfasst von Phimphitcha Ratiphunpong und 4 weiteren Autor:innen. Die Arbeit nennt 19 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).
Abstract (Originalsprache)
Background
Pancreatic steatosis and cancer are major health concerns linked to obesity and metabolic disorders. Because these conditions may alter pancreatic tissue microstructure and microcirculation, non-invasive imaging biomarkers capable of characterizing such changes are needed. Intravoxel incoherent motion diffusion-weighted imaging (IVIM-DWI) enables non-contrast quantification of diffusion and perfusion parameters, including the apparent diffusion coefficient (ADC), true diffusion coefficient (Dslow), pseudo-diffusion coefficient (Dfast), and perfusion fraction (f). However, parameter repeatability remains limitation in clinical use.
Objectives
This study aims to evaluate and compare the repeatability of Bayesian-based IVIM-DWI for pancreatic perfusion quantifications using free-breathing and respiratory-triggered acquisitions at both global and voxel levels. Materials and methods: The study consisted of two parts: (1) an evaluation using the NIST/QIBA diffusion phantom to compare image quality and ADC variability between protocols using 10 and 13 b-values, and (2) an assessment in twenty young healthy volunteers to compare within coefficient of variation (wCV) of IVIM-DWI parameters between breathing control techniques of respiratory triggering (RT) and free-breathing (FB) using a 3.0 Tesla MRI scanner.
Results
The phantom study demonstrated that the protocol with 13 b-values provided superior image quality and significantly lower ADC variability than the one with 10 b-values (p < 0.05). Meanwhile, in the volunteer study, the within-subject coefficient of variation (%wCV) of IVIM-DWI parameters did not significantly differ between RT and FB techniques (p > 0.05). However, RT exhibited lower %wCV for Dslow and f, indicating better repeatability.
Conclusion
The IVIM-DWI protocol using 13 b-values is suitable for evaluating pancreatic perfusion and offers a stable estimation of the perfusion-related f parameter. This protocol appears to be appropriate as a preliminary standard that can be refined for use in clinic. Keywords: IVIM-DWI, ADC, MRI, water diffusion, perfusion, repeatability
Zitieren
APA
Ratiphunpong, P., Sukiam, K., Arsakij, C., Klaewsarikorn, N., & Phonlakrai, M. (2026). Optimization of IVIM-Diffusion MRI protocol for Quantifying Pancreatic Perfusion between Free-breath and Respiratory triggering controls. Journal of Associated Medical Sciences, 60(1), 268-281. https://doi.org/10.66285/jams.2027.025
Vancouver
Ratiphunpong P, Sukiam K, Arsakij C, Klaewsarikorn N, Phonlakrai M. Optimization of IVIM-Diffusion MRI protocol for Quantifying Pancreatic Perfusion between Free-breath and Respiratory triggering controls. Journal of Associated Medical Sciences. 2026;60(1):268-281. doi:10.66285/jams.2027.025
BibTeX
@article{Ratiphunpong2026,
author = {Ratiphunpong, Phimphitcha and Sukiam, Kanyanat and Arsakij, Chompoonut and Klaewsarikorn, Nicharat and Phonlakrai, Monchai},
title = {Optimization of IVIM-Diffusion MRI protocol for Quantifying Pancreatic Perfusion between Free-breath and Respiratory triggering controls},
journal = {Journal of Associated Medical Sciences},
year = {2026},
volume = {60},
number = {1},
pages = {268--281},
doi = {10.66285/jams.2027.025}
}