A Framework-Guided Evaluation of EfficientNetB0 for Chest X-Ray Classification Using Grad-CAM, LIME, and SHAP
Interdisciplinary Journal of AI, Machine Learning & Data Science · 2026-11-23 · 1 (3) · e018
DOI: 10.66261/mpzsfx90 ↗At a glance
Journal article in Interdisciplinary Journal of AI, Machine Learning & Data Science, published online on 2026-11-23. Written by Kaynaat Hussain. 24 references. The full text is freely available (open access, CC BY 4.0).
Abstract (original language)
Deep neural networks can discriminate between image classes in chest radiographs, but predictive performance alone does not establish that a classifier relies on clinically meaningful evidence. This study evaluates an ImageNet-pretrained EfficientNetB0 classifier and post-hoc explanation methods using a supplied PneumoniaMNIST-derived NPZ collection whose clinical label mapping and patient-level provenance could not be independently verified. The predefined partitions contain 4,708 training, 524 validation and 624 test images. Grayscale images were represented as three-channel 224 × 224 inputs, and a frozen EfficientNetB0 backbone was trained with a binary classification head. At the fixed threshold of 0.50, test accuracy was 89.58% (95% bootstrap CI: 87.18%–91.83%) and ROC-AUC was 0.9726 (95% CI: 0.9602–0.9829). Sensitivity for numeric class 1 was 97.95% (95% CI: 96.41%–99.23%) and specificity for numeric class 0 was 75.64% (95% CI: 70.07%–80.78%). The Brier score was 0.0779 and expected calibration error was 0.0823. A threshold of 0.43 selected on the validation set using Youden’s J was evaluated separately on the test set. Grad-CAM, LIME and gradient-based SHAP outputs were generated for selected examples. Additional analyses included LIME repeated-seed stability, SHAP background-size sensitivity and exploratory deletion/insertion tests. Grad-CAM parameter randomization was partly degenerate, and a Keras input-structure warning remained in the SHAP logs; consequently, these analyses do not establish comprehensive explanation validity. Numeric classes are retained because their clinical meanings are unverified. The findings describe performance on the supplied split and do not establish patient-independent, external or clinical validation.
Cite
APA
Hussain, K. (2026). A Framework-Guided Evaluation of EfficientNetB0 for Chest X-Ray Classification Using Grad-CAM, LIME, and SHAP. Interdisciplinary Journal of AI, Machine Learning & Data Science, 1(3), e018. https://doi.org/10.66261/mpzsfx90
Vancouver
Hussain K. A Framework-Guided Evaluation of EfficientNetB0 for Chest X-Ray Classification Using Grad-CAM, LIME, and SHAP. Interdisciplinary Journal of AI, Machine Learning & Data Science. 2026;1(3):e018. doi:10.66261/mpzsfx90
BibTeX
@article{Hussain2026,
author = {Hussain, Kaynaat},
title = {A Framework-Guided Evaluation of EfficientNetB0 for Chest X-Ray Classification Using Grad-CAM, LIME, and SHAP},
journal = {Interdisciplinary Journal of AI, Machine Learning & Data Science},
year = {2026},
volume = {1},
number = {3},
pages = {e018},
doi = {10.66261/mpzsfx90}
}