EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Kinematic Calibration and Hysteresis Compensation of Cable Driven Robots for Single-Port Laparoscopy

James Thompson, Arthur Williams, Frederick Miller

International Journal of Computational and Biological Sciences · 31.01.2026 · 3 (1) · 97-106

DOI: 10.66238/ijcbs48 ↗

Kurz gefasst

Fachartikel in der Zeitschrift International Journal of Computational and Biological Sciences, online erschienen am 31.01.2026. Verfasst von James Thompson und 2 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Minimally Invasive Surgery has evolved significantly with the introduction of Single-PortAccess procedures, which reduce patient trauma by consolidating instrument entry into asingle incision. Cable-driven manipulators are the preferred mechanical solution for thesesystems due to their ability to separate bulky actuation units from the surgical end-effector.However, the transmission of motion through long, flexible cables introduces significant nonlinearities, primarily characterized by backlash, friction-induced hysteresis, and cableelongation. These factors degrade the positioning accuracy of the robot, rendering openloop control strategies insufficient for precise surgical tasks. This paper presents acomprehensive framework for the kinematic calibration and hysteresis compensation of anovel cable-driven single-port surgical robot. We propose a hybrid modeling approach thatintegrates a geometric kinematic model with a phenomenology-based hysteresiscompensation algorithm. By utilizing an iterative optimization technique based onexperimental data acquired via optical tracking, the system identifies and corrects geometricparameter errors while simultaneously compensating for viscoelastic cable behaviors. Theresults demonstrate a significant reduction in root-mean-square positioning error, validatingthe efficacy of the proposed method for enhancing the precision of flexible surgicalmanipulators.

Zitieren

APA

Thompson, J., Williams, A., & Miller, F. (2026). Kinematic Calibration and Hysteresis Compensation of Cable Driven Robots for Single-Port Laparoscopy. International Journal of Computational and Biological Sciences, 3(1), 97-106. https://doi.org/10.66238/ijcbs48

Vancouver

Thompson J, Williams A, Miller F. Kinematic Calibration and Hysteresis Compensation of Cable Driven Robots for Single-Port Laparoscopy. International Journal of Computational and Biological Sciences. 2026;3(1):97-106. doi:10.66238/ijcbs48

BibTeX
@article{Thompson2026,
  author = {Thompson, James and Williams, Arthur and Miller, Frederick},
  title = {Kinematic Calibration and Hysteresis Compensation of Cable Driven Robots for Single-Port Laparoscopy},
  journal = {International Journal of Computational and Biological Sciences},
  year = {2026},
  volume = {3},
  number = {1},
  pages = {97--106},
  doi = {10.66238/ijcbs48}
}
Kostenlos starten →