EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Position-Constrained Calibration Compensation for Hand–Eye Calibration in Industrial Robots

Jinsong Lin, Yuxing Feng, Wenze Ren iD, Jiahui Feng, Jun Zheng

Sensors · 26.11.2024 · 24 (23) · 7554

DOI: 10.3390/s24237554 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sensors, online erschienen am 26.11.2024. Verfasst von Jinsong Lin und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Mechanical Engineering, Tsinghua University, Beijing 100084, China. Die Arbeit wurde bisher 9-mal zitiert (Crossref) und nennt 20 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Tsinghua University (Department of Mechanical Engineering)-Shenzhen Chuangxin Laser Co., Ltd. Laser Advanced Manufacturing Joint Research Center Fund, Tsinghua University (Department of Mechanical Engineering), Shenzhen Chuangxin Laser Co., Ltd. Laser Advanced Manufacturing Joint Research Center Fund.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The hand–eye calibration of laser profilers and industrial robots is a critical component of the laser vision system in welding applications. To improve calibration accuracy and efficiency, this study proposes a position-constrained calibration compensation algorithm aimed at optimizing the hand–eye transformation matrix. Initially, the laser profiler is mounted on the robot and used to scan a standard sphere from various poses to obtain the theoretical center coordinates of the sphere, which are then utilized to compute the hand–eye transformation matrix. Subsequently, the positional data of the standard sphere’s surface are collected at different poses using the welding gun tip mounted on the robot, allowing for the fitting of the sphere’s center coordinates as calibration values. Finally, by minimizing the error between the theoretical and calibrated sphere center coordinates, the optimal hand–eye transformation matrix is derived. Experimental results demonstrate that, following error compensation, the average distance error in hand–eye calibration decreased from 4.5731 mm to 0.7069 mm, indicating that the proposed calibration method is both reliable and effective.

Schlagwörter

Stichwörter der Autor:innen

hand-eye calibrationline-structured light sensorspherical constraintswelding robots

Autor:innen und Institutionen

  • Department of Mechanical Engineering, Tsinghua University, Beijing 100084, China.

ORCID-Profile: Wenze Ren

Förderung

  • Tsinghua University (Department of Mechanical Engineering)-Shenzhen Chuangxin Laser Co., Ltd. Laser Advanced Manufacturing Joint Research Center Fund
  • Tsinghua University (Department of Mechanical Engineering), Shenzhen Chuangxin Laser Co., Ltd. Laser Advanced Manufacturing Joint Research Center Fund

Zitieren

APA

Lin, J., Feng, Y., Ren, W., Feng, J., & Zheng, J. (2024). Position-Constrained Calibration Compensation for Hand–Eye Calibration in Industrial Robots. Sensors, 24(23), 7554. https://doi.org/10.3390/s24237554

Vancouver

Lin J, Feng Y, Ren W, Feng J, Zheng J. Position-Constrained Calibration Compensation for Hand–Eye Calibration in Industrial Robots. Sensors. 2024;24(23):7554. doi:10.3390/s24237554

BibTeX
@article{Lin2024,
  author = {Lin, Jinsong and Feng, Yuxing and Ren, Wenze and Feng, Jiahui and Zheng, Jun},
  title = {Position-Constrained Calibration Compensation for Hand–Eye Calibration in Industrial Robots},
  journal = {Sensors},
  year = {2024},
  volume = {24},
  number = {23},
  pages = {7554},
  doi = {10.3390/s24237554}
}