EUVIMEDEUVIMED entdecken
Crossref

Dynamic Cyclic Fatigue Resistance and Bending Stiffness of Blue-Treated NiTi Rotary Instruments at Simulated Intracanal Temperature: A Comparative In Vitro Study

Taher Al Omari, Anas Al Jadaa, Yazan Al-Zain, Haytham Abdulazziz, Amre R. Atmeh, Rashid El Abed

European Endodontic Journal · 30.07.2026

DOI: 10.65717/eej.2026.26062. ↗

Kurz gefasst

Fachartikel in der Zeitschrift European Endodontic Journal, online erschienen am 30.07.2026. Verfasst von Taher Al Omari und 5 weiteren Autor:innen.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

To compare the dynamic cyclic fatigue resistance, bending stiffness and phase transformation characteristics of blue heat-treated instruments, VDW Rotate (VR) and Azur Blue (AzB), at a simulated intracanal temperature of 34 ± 1°C.

Methods

Fifty-eight new instruments (n=29 per group) were allocated as follows: dynamic cyclic fatigue testing (n=12), bending stiffness evaluation (n=12), differential scanning calorimetry (DSC) (n=1), X-ray diffraction (XRD) (n=2) and energy-dispersive X-ray fluorescence (EDXRF) (n=2). Dynamic cyclic fatigue testing was conducted in an artificial canal (18 mm length, 1.4 mm diameter, 45° curvature, 5 mm radius) at 34 ± 1°C. Time to fracture was recorded and converted to the number of cycles to failure, and fractured segment lengths were measured. Bending stiffness was evaluated with a 3 mm deflection range at 34 ± 1°C. Differential scanning calorimetry, energy-dispersive X-ray fluorescence, X-ray diffraction and scanning electron microscopy were used for metallurgical and fractographic analyses.

Results

Differential scanning calorimetry revealed austenitic finish temperatures (AuF) of 35.8°C for VDW Rotate and 39.4°C for AzB. Azur Blue showed significantly higher cyclic fatigue resistance (2039 ± 250 vs. 1609 ± 222 cycles), lower bending stiffness (0.85 ± 0.07 vs. 1.07 ± 0.08 N) and longer fractured fragment length (4.87± 0.44 vs. 3.27 ± 0.75 mm) than VDW Rotate (P < .05).

Conclusion

Azur Blue showed higher cyclic fatigue resistance, whereas VDW Rotate showed higher bending stiffness. These differences were more consistently associated with phase transformation behaviour than with external geometry alone.

Zitieren

APA

Omari, T. A., Jadaa, A. A., Al-Zain, Y., Abdulazziz, H., Atmeh, A. R., & Abed, R. E. (2026). Dynamic Cyclic Fatigue Resistance and Bending Stiffness of Blue-Treated NiTi Rotary Instruments at Simulated Intracanal Temperature: A Comparative In Vitro Study. European Endodontic Journal. https://doi.org/10.65717/eej.2026.26062.

Vancouver

Omari TA, Jadaa AA, Al-Zain Y, Abdulazziz H, Atmeh AR, Abed RE. Dynamic Cyclic Fatigue Resistance and Bending Stiffness of Blue-Treated NiTi Rotary Instruments at Simulated Intracanal Temperature: A Comparative In Vitro Study. European Endodontic Journal. 2026. doi:10.65717/eej.2026.26062.

BibTeX
@article{Omari2026,
  author = {Omari, Taher Al and Jadaa, Anas Al and Al-Zain, Yazan and Abdulazziz, Haytham and Atmeh, Amre R. and Abed, Rashid El},
  title = {Dynamic Cyclic Fatigue Resistance and Bending Stiffness of Blue-Treated NiTi Rotary Instruments at Simulated Intracanal Temperature: A Comparative In Vitro Study},
  journal = {European Endodontic Journal},
  year = {2026},
  doi = {10.65717/eej.2026.26062.}
}
Kostenlos starten →