EUVIMEDEUVIMED entdecken
Crossref

Assessment of Slot Dimension Variability in Metal and Ceramic Orthodontic Brackets

Ahmet Yıldırım

Clinical Dentistry and Research · 29.04.2026 · 50 (1) · 23-29

DOI: 10.65022/clindentres.1782679 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Clinical Dentistry and Research, online erschienen am 29.04.2026. Verfasst von Ahmet Yıldırım. Die Arbeit nennt 20 Literaturangaben.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background and Aim: This study aims to evaluate thecompatibility between the manufacturer-declared and the actualmeasured slot dimensions of different commercially availableorthodontic brackets.Materials and Methods: In this study, the vertical slotdimensions of orthodontic brackets produced from differentmaterials and manufacturing techniques were comparativelyanalyzed. Measurements were obtained from microscopicimages of 15 metal and 15 ceramic brackets, and slot heightwas measured both near the base and at the open edge of thebrackets. The data were subsequently evaluated through intragroupanalyses as well as by comparison with the manufacturerstateddimensions.

Results

In the study, the upper edges of the slots in bothbracket groups were found to be significantly wider than thebase, indicating a statistically significant difference. Thesefindings suggest that the slots exhibit a slightly divergentconfiguration. Moreover, the mean slot heights of both metal andceramic brackets were found to be significantly greater than themanufacturer-specified value of 0.022 inches (p < 0.001).

Conclusion

The findings of the study indicate that orthodonticbracket slots may be wider than the dimensions stated by themanufacturers, which may lead to unintended deviations in thethree-dimensional positioning of teeth. This highlights the needfor clinicians to exercise caution. In this context, considering thatincreased slot dimensions can compromise tooth movementcontrol, it is recommended to use archwires that better fill theslot or to implement compensatory measures such as wirebending.

Zitieren

APA

Yıldırım, A. (2026). Assessment of Slot Dimension Variability in Metal and Ceramic Orthodontic Brackets. Clinical Dentistry and Research, 50(1), 23-29. https://doi.org/10.65022/clindentres.1782679

Vancouver

Yıldırım A. Assessment of Slot Dimension Variability in Metal and Ceramic Orthodontic Brackets. Clinical Dentistry and Research. 2026;50(1):23-29. doi:10.65022/clindentres.1782679

BibTeX
@article{Yldrm2026,
  author = {Yıldırım, Ahmet},
  title = {Assessment of Slot Dimension Variability in Metal and Ceramic Orthodontic Brackets},
  journal = {Clinical Dentistry and Research},
  year = {2026},
  volume = {50},
  number = {1},
  pages = {23--29},
  doi = {10.65022/clindentres.1782679}
}
Kostenlos starten →