EUVIMEDEUVIMED entdecken
Crossref

Breast Tumor Classification Based on the Scatterer Spacing Estimated with Matching Pursuit

Xiuhua Zeng, Wenzhi Xia, Zhengwei Wang, Taoxiang Yang

PhysioPlus Open · 2025

DOI: 10.64473/ppo.02.02.032 ↗

Kurz gefasst

Fachartikel in der Zeitschrift PhysioPlus Open, 2025. Verfasst von Xiuhua Zeng und 3 weiteren Autor:innen.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Mean Scatterer Spacing (MSS) estimated from ultrasound radiofrequency (RF) echo signals provides valuable microstructural information for breast tumor characterization. However, conventional MSS estimation methods suffer from limited noise robustness, low objectivity, and strong dependence on signal assumptions.

Objective

This study aims to develop an objective and noise-robust approach for estimating MSS to improve the differentiation between benign and malignant breast tumors.

Methods

A Matching Pursuit (MP)–based method is proposed to decompose ultrasound RF echo signals using a redundant Gabor atom dictionary. The Second-Order Difference (SOD) of the Reconstructed Signal-to-Residual Ratio (RSRR) is employed to automatically identify Gabor atoms corresponding to coherent scattering components while suppressing diffuse scattering and noise. Inter-Scatterer Spacing (ISS) and MSS are then estimated from the spatial locations of the selected atoms. The method was evaluated on the OASBUD database, including 48 benign and 52 malignant breast lesion regions of interest.

Results

The estimated mean ISS for benign lesions was 0.81 ± 0.10 mm, which was significantly higher than that of malignant lesions (0.75 ± 0.12 mm). One-way ANOVA analysis confirmed a statistically significant difference between the two groups (p = 0.024).

Conclusion

The proposed MP-based MSS estimation approach enhances the accuracy, stability, and objectivity of scatterer spacing estimation from ultrasound RF signals. By effectively isolating coherent tissue microstructures, the method provides a reliable quantitative tool for distinguishing benign and malignant breast tumors and shows strong potential for clinical ultrasound tissue characterization.

Zitieren

APA

Zeng, X., Xia, W., Wang, Z., & Yang, T. (2025). Breast Tumor Classification Based on the Scatterer Spacing Estimated with Matching Pursuit. PhysioPlus Open. https://doi.org/10.64473/ppo.02.02.032

Vancouver

Zeng X, Xia W, Wang Z, Yang T. Breast Tumor Classification Based on the Scatterer Spacing Estimated with Matching Pursuit. PhysioPlus Open. 2025. doi:10.64473/ppo.02.02.032

BibTeX
@article{Zeng2025,
  author = {Zeng, Xiuhua and Xia, Wenzhi and Wang, Zhengwei and Yang, Taoxiang},
  title = {Breast Tumor Classification Based on the Scatterer Spacing Estimated with Matching Pursuit},
  journal = {PhysioPlus Open},
  year = {2025},
  doi = {10.64473/ppo.02.02.032}
}
Kostenlos starten →