EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

ICEEMDAN–power cepstrum framework for mean scatterer spacing estimation in breast and porcine liver tissues with microwave ablation validation

Ouissem Chibani Bahi, Saadia Benhalouche, Abdelhafid Kaddour iD, Wei-Jiang Xu

Biomedical Engineering / Biomedizinische Technik · 06.05.2026

DOI: 10.1515/bmt-2025-0101 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biomedical Engineering / Biomedizinische Technik, online erschienen am 06.05.2026. Verfasst von Ouissem Chibani Bahi und 3 weiteren Autor:innen. Beteiligte Einrichtung: Signals, Systems and Data Laboratory (LSSD), Electronic Department, University of Sciences and Technology of Oran USTO-MB, Bir El Djir, Oran, Algeria. Die Arbeit nennt 63 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objectives

To introduce ICEEMDAN–PC, a novel quantitative ultrasound (QUS) approach for accurate and noise-robust estimation of mean scatterer spacing (MSS), enabling refined characterization of liver and breast tissue microstructures in health, disease, and post-treatment states.

Methods

ICEEMDAN–PC integrates the improved complete ensemble empirical mode decomposition with adaptive noise (ICEEMDAN) and power cepstrum (PC). The intrinsic mode function with the highest energy is extracted, and its cepstrum is analyzed to determine MSS. The method was validated using 30,100 simulated noisy RF signals (semi-periodic/diffuse scatterers) and applied to: (1) 301 ex vivo porcine liver signals, (2) 31,488 paired RF signals pre/post microwave ablation (MWA), and (3) RF data from 100 clinical breast lesions (52 malignant, 48 benign).

Results

Simulations recovered the theoretical MSS (1.25 mm) with low variance despite high noise. In a healthy liver, MSS was 1.02 mm, with significant shifts post-MWA indicating microstructural disruption. Breast lesion MSS values (0.8736 mm benign, 0.9068 mm malignant) matched literature trends.

Conclusions

ICEEMDAN–PC consistently achieved high accuracy and sensitivity across simulated, experimental, and clinical datasets, demonstrating strong potential for non-invasive QUS-based tissue characterization and therapeutic monitoring.

Schlagwörter

Stichwörter der Autor:innen

ICEEMDANbackscattered RF signalsbreast lesionsmean scatterer spacingporcine liverpower cepstrum

Autor:innen und Institutionen

  • Signals, Systems and Data Laboratory (LSSD), Electronic Department, University of Sciences and Technology of Oran USTO-MB, Bir El Djir, Oran, Algeria.
  • Analysis and Application of Radiation Laboratory (LAAR), Physics Department, University of Sciences and Technology of Oran USTO-MB, Bir El Djir, Oran, Algeria.
  • Laboratoire IEMN-site de Valenciennes, CNRS, Université Polytechnique Hauts-de-France, NSA, Valenciennes, France.

ORCID-Profile: Abdelhafid Kaddour

Zitieren

APA

Chibani Bahi, O., Benhalouche, S., Kaddour, A., & Xu, W. J. (2026). ICEEMDAN–power cepstrum framework for mean scatterer spacing estimation in breast and porcine liver tissues with microwave ablation validation. Biomedical Engineering / Biomedizinische Technik. https://doi.org/10.1515/bmt-2025-0101

Vancouver

Chibani Bahi O, Benhalouche S, Kaddour A, Xu WJ. ICEEMDAN–power cepstrum framework for mean scatterer spacing estimation in breast and porcine liver tissues with microwave ablation validation. Biomedical Engineering / Biomedizinische Technik. 2026. doi:10.1515/bmt-2025-0101

BibTeX
@article{ChibaniBahi2026,
  author = {Chibani Bahi, Ouissem and Benhalouche, Saadia and Kaddour, Abdelhafid and Xu, Wei-Jiang},
  title = {ICEEMDAN–power cepstrum framework for mean scatterer spacing estimation in breast and porcine liver tissues with microwave ablation validation},
  journal = {Biomedical Engineering / Biomedizinische Technik},
  year = {2026},
  doi = {10.1515/bmt-2025-0101}
}
Kostenlos starten →