EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 3.0

Pseudomyopia and cycloplegic changes in young cynomolgus macaques

Guitong Ye, Yuan Zhang, Kezhe Chen, Rui Xie, Wei Liu, Chiwai Wong, Jinan Zhan, Ruiyu Luo, Shaofen Huang, Xiaohua Zhuo, Jian Wu, Yunxia Leng und 3 weitere

Molecular Vision · 25.12.2025 · 31 · 539-552

DOI: 10.63500/mv_v31_539 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Molecular Vision, online erschienen am 25.12.2025. Verfasst von Guitong Ye und 14 weiteren Autor:innen. Die Arbeit nennt 55 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 3.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

Primate eyes feature a physiologic accommodative system identical to that of humans. Nonetheless, their biometric changes before and after cycloplegia have not been investigated. In this study, we aimed to evaluate the characteristics of pseudomyopia and explore factors associated with cycloplegic changes in young cynomolgus macaques.

Methods

Refractive and biometric measurements were performed on both eyes before and after cycloplegia in 88 cynomolgus macaques aged 3−6 years without ocular diseases. Pseudomyopia was defined as autorefraction-estimated noncycloplegic spherical equivalent (NSE) < −0.50 D and cycloplegic spherical equivalent (CSE) ≥ −0.50 D. Linear mixed models were established to identify factors associated with cycloplegic differences.

Results

After excluding low-quality ophthalmic data, 149 eyes were included in the final analysis. The median NSE was −0.38 (interquartile range: −1.50, 0.25) D and the median CSE was 0.13 (−0.50, 0.90) D, exhibiting a robust Pearson’s correlation coefficient of 0.89 (95% confidence interval: 0.78−0.92). Pseudomyopia was observed in 35 of the 149 eyes, with a greater hyperopic shift (median, 1.42 D) compared to that in non-myopic and true-myopic eyes (median, 0.50 D for both, p<0.001). Pseudomyopic eyes demonstrated active accommodation before cycloplegia and exhibited biometric changes after cycloplegia akin to those in true-myopic eyes. Under cycloplegia, non-myopic and pseudomyopic eyes exhibited similar biometric measurements. A greater hyperopic shift correlated with a higher hyperopic NSE and greater reductions in lens thickness.

Conclusions

The use of 1% cyclopentolate yielded discernible alterations in refractive and biometric parameters in 3- to 6-year-old cynomolgus macaques. Notably, compared with non-myopia and true myopia, pseudomyopia exhibited associations and discrepancies in accommodative status. These findings underscore the importance of investigating the role of the lens in animal models employed in myopia research.

Zitieren

APA

Ye, G., Zhang, Y., Chen, K., Xie, R., Liu, W., Wong, C., Zhan, J., Luo, R., Huang, S., Zhuo, X., Wu, J., Leng, Y., Zhuo, Y., Fu, M., & Zhu, Y. (2025). Pseudomyopia and cycloplegic changes in young cynomolgus macaques. Molecular Vision, 31, 539-552. https://doi.org/10.63500/mv_v31_539

Vancouver

Ye G, Zhang Y, Chen K, Xie R, Liu W, Wong C, et al. Pseudomyopia and cycloplegic changes in young cynomolgus macaques. Molecular Vision. 2025;31:539-552. doi:10.63500/mv_v31_539

BibTeX
@article{Ye2025,
  author = {Ye, Guitong and Zhang, Yuan and Chen, Kezhe and Xie, Rui and Liu, Wei and Wong, Chiwai and Zhan, Jinan and Luo, Ruiyu and Huang, Shaofen and Zhuo, Xiaohua and Wu, Jian and Leng, Yunxia and Zhuo, Yehong and Fu, Min and Zhu, Yingting},
  title = {Pseudomyopia and cycloplegic changes in young cynomolgus macaques},
  journal = {Molecular Vision},
  year = {2025},
  volume = {31},
  pages = {539--552},
  doi = {10.63500/mv_v31_539}
}
Kostenlos starten →