EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Comparative Accuracy of Cycloplegic and Non-Cycloplegic Autorefraction in Young Adults

Irfana Bibi, Faiza Akhtar, Ammara Tahir, Iqra Farhat, Sania Arif, Tahira Jabeen

Annals of King Edward Medical University · 30.06.2026 · 32 (2)

DOI: 10.21649/akemu.v32i2.5800 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Annals of King Edward Medical University, online erschienen am 30.06.2026. Verfasst von Irfana Bibi und 5 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Cycloplegic refraction is the standard for accurate measurement of refractive errors in children; however, its necessity in young adults remains debated. This study aimed to determine whether it is required in adults as well.

Objectives

To compare the accuracy of cycloplegic and non-cycloplegic autorefraction in young adults and to quantify the difference in spherical equivalent (SE).

Methods

A quasi-experimental study was conducted on 158 eyes of 79 subjects (aged 18–25 years) at the Ophthalmology Department, Mayo Hospital, Lahore. The average spherical equivalent (SE) was calculated before and after cycloplegia using an autorefractometer (Canon RK-5). Each eye was classified based on spherical equivalent (SE) as myopic when SE ≤ −0.50 D, emmetropic when −0.50 D < SE < +0.50 D, and hyperopic when SE ≥ +0.50 D. Cycloplegia was achieved with Cyclopentolate (1%) eye drops instilled three times, with an interval of 10 minutes to attain full cycloplegia. Data was analysed by SPSS-23. A p-value ≤ 0.05 was considered statistically significant.

Results

The mean difference between non-cycloplegic and cycloplegic SE was statistically significant (P = 0.011). A strong correlation was found between pre- and post-cycloplegic sphere (r = 0.951), SE (r = 0.967), and cylindrical values (r = 0.989). The mean difference between non-cycloplegic and cycloplegic refraction was +1.26 D in hyperopic and +0.50 D in myopic eyes.

Conclusion

Cycloplegic autorefraction produced a hyperopic shift of +0.16 D that was statistically significant but clinically negligible. It may not be required routinely except in cases of latent hyperopia or accommodative spasm.

Zitieren

APA

Bibi, I., Akhtar, F., Tahir, A., Farhat, I., Arif, S., & Jabeen, T. (2026). Comparative Accuracy of Cycloplegic and Non-Cycloplegic Autorefraction in Young Adults. Annals of King Edward Medical University, 32(2). https://doi.org/10.21649/akemu.v32i2.5800

Vancouver

Bibi I, Akhtar F, Tahir A, Farhat I, Arif S, Jabeen T. Comparative Accuracy of Cycloplegic and Non-Cycloplegic Autorefraction in Young Adults. Annals of King Edward Medical University. 2026;32(2). doi:10.21649/akemu.v32i2.5800

BibTeX
@article{Bibi2026,
  author = {Bibi, Irfana and Akhtar, Faiza and Tahir, Ammara and Farhat, Iqra and Arif, Sania and Jabeen, Tahira},
  title = {Comparative Accuracy of Cycloplegic and Non-Cycloplegic Autorefraction in Young Adults},
  journal = {Annals of King Edward Medical University},
  year = {2026},
  volume = {32},
  number = {2},
  doi = {10.21649/akemu.v32i2.5800}
}
Kostenlos starten →