EUVIMEDOpdag EUVIMED
Open access · CC BY 4.0

Efficacy of Open Reduction and Internal Fixation Assisted by Handheld Ultrasound Combined with 3D Printing Technology in Treating Multiple Rib Fractures

Jieshi Li, Qianshun Chen, Xunyu Xu, Yimeng Zhuo, Minhui Zhang, Dong Zhou, Zhong Li

Annali Italiani di Chirurgia · 2025

DOI: 10.62713/aic.3612 ↗

At a glance

Journal article in Annali Italiani di Chirurgia, 2025. Written by Jieshi Li and 6 co-authors. Institution: Department of Thoracic Surgery, Mindong Hospital Affiliated to Fujian Medical University, 355000 Fu'an, Fujian China. Major MEDLINE topics: Rib Fractures, Printing, Three-Dimensional, Fracture Fixation, Internal, Open Fracture Reduction. Cited 4 times so far (Crossref). The full text is freely available (open access, CC BY 4.0).

AbstractSubjectsBibliografiske oplysningerCiteRelated studies

Abstract (original language)

AIM: This study aimed to explore the efficacy of open reduction and internal fixation assisted by handheld ultrasound combined with three-dimensional (3D) printing technology in treating multiple rib fractures. METHODS: We retrospectively analyzed the clinical data from 84 patients affected with multiple rib fractures admitted to our hospital between August 2022 and April 2024. After excluding four cases, 80 cases were included in this study. Based on the method of preoperative rib fracture localization, patients were divided into three groups: group A (n = 30), group B (n = 26), and group C (n = 24). Group A received 3D reconstruction of ribs on chest Computed Tomography (CT), group B adopted the examination of handheld ultrasound and 3D reconstruction of ribs on chest CT, and group C received handheld ultrasound, 3D reconstruction of ribs on chest CT, and 3D printing technology. The operation-related indicators (such as incision length, exposure time of surgical field, intraoperative blood loss), pulmonary function [total lung capacity (TLC), forced vital capacity (FVC), forced expiratory volume in one second/forced vital capacity (FEV1/FVC), residual volume (RV)], quality of life, degree of pain, and incidence of complications were compared among the three groups. RESULTS: Before surgery, there were no significant differences in pulmonary function, quality of life, and degree of pain among the three groups (p > 0.05). However, after surgery, significant differences in the pairwise comparison of TLC, FVC, FEV1/FVC and RV were observed among the three groups (p < 0.001), with group C indicating the highest levels of observational indicators and group A exhibiting the lowest levels. Furthermore, a significant difference was observed in the pairwise comparison of incision length, exposure time of surgical field, and intraoperative blood loss among the three groups (p < 0.001). Group C had the shortest incision length, the lowest exposure time in the surgical field, and the least intraoperative blood loss, while those in group A were the opposite. After surgery, a significant difference was found in the pairwise comparison of the quality of life and degree of pain among the three groups (p 0.05). CONCLUSIONS: The open reduction and internal fixation assisted by handheld ultrasound combined with 3D printing technology revealed effective curative outcomes in treating multiple rib fractures. This method promotes the formulation of an accurate and personalized surgical plan and seems to have high clinical significance.

Subjects

MeSH terms (MEDLINE)

Rib FracturesPrinting, Three-DimensionalFracture Fixation, InternalOpen Fracture ReductionFractures, MultipleHumansMaleFemaleRetrospective StudiesMiddle AgedAdultTreatment OutcomeUltrasonographyAgedTomography, X-Ray ComputedQuality of Life

Authors and institutions

  • Department of Thoracic Surgery, Mindong Hospital Affiliated to Fujian Medical University, 355000 Fu'an, Fujian China.
  • Department of Thoracic Surgery, Fujian Provincial Hospital, Fuzhou University Affiliated Provincial Hospital, 350000 Fuzhou, Fujian, China.
  • Department of Orthopaedics, Mindong Hospital Affiliated to Fujian Medical University, 355000 Fu'an, Fujian, China.

Cite

APA

Li, J., Chen, Q., Xu, X., Zhuo, Y., Zhang, M., Zhou, D., & Li, Z. (2025). Efficacy of Open Reduction and Internal Fixation Assisted by Handheld Ultrasound Combined with 3D Printing Technology in Treating Multiple Rib Fractures. Annali Italiani di Chirurgia. https://doi.org/10.62713/aic.3612

Vancouver

Li J, Chen Q, Xu X, Zhuo Y, Zhang M, Zhou D, et al. Efficacy of Open Reduction and Internal Fixation Assisted by Handheld Ultrasound Combined with 3D Printing Technology in Treating Multiple Rib Fractures. Annali Italiani di Chirurgia. 2025. doi:10.62713/aic.3612

BibTeX
@article{Li2025,
  author = {Li, Jieshi and Chen, Qianshun and Xu, Xunyu and Zhuo, Yimeng and Zhang, Minhui and Zhou, Dong and Li, Zhong},
  title = {Efficacy of Open Reduction and Internal Fixation Assisted by Handheld Ultrasound Combined with 3D Printing Technology in Treating Multiple Rib Fractures},
  journal = {Annali Italiani di Chirurgia},
  year = {2025},
  doi = {10.62713/aic.3612}
}
Start for free →