EUVIMEDEUVIMED entdecken
Systematische Übersicht

LOW-TEMPERATURE STERILIZATION OF HEAT-SENSITIVE MEDICAL DEVICES: A SYSTEMATIC REVIEW OF MICROBIAL EFFICACY AND MATERIAL COMPATIBILITY

Acta Innovations · 03.11.2026 · 64 (2s)

DOI: 10.62441/actainnovations.vi.3257 ↗

Kurz gefasst

Systematische Übersicht in der Zeitschrift Acta Innovations, online erschienen am 03.11.2026.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Low-temperature sterilization provides processing options for medical devices that cannot tolerate conventional steam sterilization. Its suitability depends on achieving microbial inactivation while preserving material integrity and device function.

Objective

To evaluate the microbial efficacy and material compatibility of low-temperature sterilization methods for heat-sensitive medical devices, considering device characteristics, processing conditions, and repeated exposure.

Methods

A systematic review is planned using MEDLINE, Embase, Scopus, and Web of Science, supplemented by citation searching. Eligible primary studies will report microbial efficacy, material compatibility, or both. Two reviewers will independently assess eligibility and methodological limitations. Findings will undergo structured narrative synthesis, with meta-analysis considered where studies are sufficiently comparable. The present abstract summarizes a preliminary synthesis of four verified primary studies; systematic screening and formal appraisal remain outstanding.Preliminary Results: Comparative laboratory studies reported differences in microbial inactivation across sterilization systems under specified contamination and device-challenge conditions. A study of selected three-dimensional printed materials supported vaporized hydrogen peroxide sterilization within defined material and design limits. A separate investigation of seven epoxy formulations exposed to 100 vaporized hydrogen peroxide cycles classified six as compatible and one as incompatible because of changes in texture and hardness. Differences in experimental conditions and outcomes prevented a defensible overall ranking of technologies. No pooled estimates were calculated.

Conclusion

The preliminary evidence supports evaluating specific device–process combinations using both microbial and compatibility outcomes. Favorable findings in either domain alone cannot establish overall suitability. Definitive comparative conclusions require completion of the systematic search, eligibility assessment, and methodological appraisal.

Zitieren

APA

(2026). LOW-TEMPERATURE STERILIZATION OF HEAT-SENSITIVE MEDICAL DEVICES: A SYSTEMATIC REVIEW OF MICROBIAL EFFICACY AND MATERIAL COMPATIBILITY. Acta Innovations, 64(2s). https://doi.org/10.62441/actainnovations.vi.3257

Vancouver

LOW-TEMPERATURE STERILIZATION OF HEAT-SENSITIVE MEDICAL DEVICES: A SYSTEMATIC REVIEW OF MICROBIAL EFFICACY AND MATERIAL COMPATIBILITY. Acta Innovations. 2026;64(2s). doi:10.62441/actainnovations.vi.3257

BibTeX
@article{euvimed2026,
  title = {LOW-TEMPERATURE STERILIZATION OF HEAT-SENSITIVE MEDICAL DEVICES: A SYSTEMATIC REVIEW OF MICROBIAL EFFICACY AND MATERIAL COMPATIBILITY},
  journal = {Acta Innovations},
  year = {2026},
  volume = {64},
  number = {2s},
  doi = {10.62441/actainnovations.vi.3257}
}
Kostenlos starten →