Design and Experimental Evaluation of a Small-Scale Pumped Storage Hydropower System with a Low-Head Pelton Turbine Integrated with an Off-Grid Solar PV System

Gde Atmajaya, Harry Yuliansyah, Ali Muhtar

Techno.Com · 28.05.2026 · 25 (2) · 295-307

DOI: 10.62411/tc.v25i2.15971 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Techno.Com, online erschienen am 28.05.2026. Verfasst von Gde Atmajaya und 2 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This study presents the design and experimental evaluation of a small-scale pumped-storage hydropower (PSH) system integrated with an off-grid photovoltaic (PV) system, serving as a proof-of-concept energy storage prototype. The proposed system consisted of an 800 Wp PV array, an upper and lower reservoir, a low-head Pelton turbine, a DC generator, piping, and a water pump. The system was implemented in a building-based configuration with an effective storage head of 14.65 m. The research was conducted using an engineering design approach, including site assessment, turbine design, turbine-generator testing, PSH-PV integration, and system performance evaluation. The PV subsystem showed a positive linear relationship between solar irradiance and PV output power, indicating an appropriate electrical response under field operating conditions. During the charging test, the nominal 550 L upper reservoir was filled with an actual water volume of 462 L, resulting in a stored potential energy of 18.44 Wh. The estimated electrical input energy required for charging was 105.30 Wh, corresponding to a storage efficiency of 17.51%. During the discharge test, the turbine-generator unit operated for approximately 0.61 h while the tank was being emptied and produced an electrical output energy of 5.76 Wh. DC output power generally ranged from 8.46 W to 10.03 W during the main discharge phase before dropping sharply near the end of operation. The turbine-generator efficiency was 31.24%, while the overall recoverable efficiency of the integrated PSH system was 5.47%. The results confirm the technical feasibility of the proposed PSH-PV system as a small-scale energy storage prototype. However, the relatively low storage efficiency and overall recoverable efficiency indicate that further optimization is required before practical implementation. Keywords: Pumped Storage Hydropower, Pelton Turbine, Renewable Energy, Photovoltaic System, Energy Storage

Zitieren

APA

Atmajaya, G., Yuliansyah, H., & Muhtar, A. (2026). Design and Experimental Evaluation of a Small-Scale Pumped Storage Hydropower System with a Low-Head Pelton Turbine Integrated with an Off-Grid Solar PV System. Techno.Com, 25(2), 295-307. https://doi.org/10.62411/tc.v25i2.15971

Vancouver

Atmajaya G, Yuliansyah H, Muhtar A. Design and Experimental Evaluation of a Small-Scale Pumped Storage Hydropower System with a Low-Head Pelton Turbine Integrated with an Off-Grid Solar PV System. Techno.Com. 2026;25(2):295-307. doi:10.62411/tc.v25i2.15971

BibTeX
@article{Atmajaya2026,
  author = {Atmajaya, Gde and Yuliansyah, Harry and Muhtar, Ali},
  title = {Design and Experimental Evaluation of a Small-Scale Pumped Storage Hydropower System with a Low-Head Pelton Turbine Integrated with an Off-Grid Solar PV System},
  journal = {Techno.Com},
  year = {2026},
  volume = {25},
  number = {2},
  pages = {295--307},
  doi = {10.62411/tc.v25i2.15971}
}