EUVIMEDEUVIMED entdecken
Open Access

Endobutton plates demonstrate superior efficacy in treating unstable distal clavicle fractures

Xiaomin Wang, Dawei Chen, Li Li, Wenbin He, Fang Wang

American Journal of Translational Research · 2024 · 16 (12) · 7840-7848

DOI: 10.62347/nxho5858 ↗

Kurz gefasst

Fachartikel in der Zeitschrift American Journal of Translational Research, 2024. Verfasst von Xiaomin Wang und 4 weiteren Autor:innen. Beteiligte Einrichtung: Shanghai East Hospital (East Hospital Affiliated to Tongji University) Shanghai 200120, China. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 26 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

OBJECTIVE: To compare the effectiveness of clavicular hook plates and Endobutton plates in treating unstable distal clavicle fractures (UDCFs). METHODS: Data from 95 patients with UDCFs (Neer II and V types) were retrospectively analyzed. Among them, 55 cases were treated with clavicular hook plates (control group), and 40 cases with Endobutton plates (research group). Comparative analyses included intraoperative indicators (incision length, intraoperative blood loss, operation time), postoperative recovery metrics (fracture healing time, fracture displacement distance, hospitalization time), pain assessment (Visual Analogue Scale [VAS]), shoulder joint function (American Shoulder and Elbow Surgeons [ASES] questionnaire), postoperative complications (plate loosening, recurrent fractures, incision infection, and fracture end redisplacement), and overall clinical efficacy. RESULTS: The research group demonstrated significantly shorter incision lengths, comparable intraoperative blood loss, longer operation times, and shorter fracture healing times compared to the control group (all P 0.05). However, VAS scores were significantly lower, while ASES scores (pain, function, and total) were notably higher in the research group (all P 0.05), but the excellent and good treatment rate was significantly higher in the research group (P < 0.05). CONCLUSIONS: Endobutton plates offer significantly better clinical outcomes compared to clavicular hook plates for treating UDCFs, demonstrating advantages in postoperative recovery, pain management, and functional improvement.

Schlagwörter

Stichwörter der Autor:innen

Clavicular hook platesclinical effectcontrolled studyendobutton platesunstable distal clavicle fractures

Autor:innen und Institutionen

  • Shanghai East Hospital (East Hospital Affiliated to Tongji University) Shanghai 200120, China.

Zitieren

APA

Wang, X., Chen, D., Li, L., He, W., & Wang, F. (2024). Endobutton plates demonstrate superior efficacy in treating unstable distal clavicle fractures. American Journal of Translational Research, 16(12), 7840-7848. https://doi.org/10.62347/nxho5858

Vancouver

Wang X, Chen D, Li L, He W, Wang F. Endobutton plates demonstrate superior efficacy in treating unstable distal clavicle fractures. American Journal of Translational Research. 2024;16(12):7840-7848. doi:10.62347/nxho5858

BibTeX
@article{Wang2024,
  author = {Wang, Xiaomin and Chen, Dawei and Li, Li and He, Wenbin and Wang, Fang},
  title = {Endobutton plates demonstrate superior efficacy in treating unstable distal clavicle fractures},
  journal = {American Journal of Translational Research},
  year = {2024},
  volume = {16},
  number = {12},
  pages = {7840--7848},
  doi = {10.62347/nxho5858}
}
Kostenlos starten →