EUVIMEDEUVIMED entdecken
Vergleichsstudie

Comparative clinical outcomes and radiological images of clavicle hook plate versus Scorpion Plate® for unstable distal clavicle fractures

Naoki Takatori, Yoshiyasu Uchiyama, Eiji Shimpuku, Takeshi Imai, Masahiko Watanabe

Journal of Orthopaedic Science · 2025-03 · 30 (2) · 307-312

DOI: 10.1016/j.jos.2024.06.003 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Journal of Orthopaedic Science, 2025-03. Verfasst von Naoki Takatori und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopaedic Surgery, Tokai University Hachioji Hospital, 1838 Ishikawacho, Hachiojishi, Tokyo 192-0032, Japan; Department of Orthopaedi…. Hauptthemen laut MEDLINE: Clavicle, Bone Plates, Fractures, Bone, Fracture Fixation, Internal. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 26 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Although various surgical methods are available for unstable distal clavicle fractures, consensus remains lacking on the optimal technique. Therefore, the present retrospective study aimed to compare the clavicle hook plate and Scorpion Plate® in terms of clinical outcomes and radiological findings for unstable distal clavicle fractures. METHODS: Fifty-seven patients with unstable distal clavicle fractures who underwent treatment using a clavicle hook plate (Group H; 28 patients) or Scorpion Plate® (Group S; 29 patients) were included in the present study. No patients received additional augmentation and all were followed-up for >1 year (mean follow-up, 28 months). Clinical outcomes were operation time, bleeding volume, complications, range of motion (ROM) at 6 months after surgery and final follow-up, and clinical scores (Constant-Murley score and University of California, Los Angeles (UCLA) shoulder score). Radiological outcomes assessed were coracoclavicular distance (CCD), difference in CCD between affected and non-affected sides (ΔCCD), and acromioclavicular subluxation ratio (%ACS) from plain X-rays. The χ2 test and Mann-Whitney U test were used to compare each outcome. RESULTS: Complications were seen in 3 shoulders (10.7%) in Group H. ROM was significantly worse in Group H at 6 months postoperatively, but no significant differences between groups were evident at final follow-up. Moreover, no significant differences in clinical outcomes were seen between groups. In terms of radiological results, Group H showed greater improvement in CCD and ΔCCD than Group S. Further, %ACS was significantly worse in Group S. CONCLUSIONS: The clavicle hook plate allows reconstruction of a more anatomical position than the Scorpion Plate®, but carries a greater risk of complications. Conversely, the Scorpion Plate® has a low risk of complications, but acromioclavicular subluxation remains. However, no significant differences in ROM or clinical outcomes were apparent at final follow-up.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

ClavicleBone PlatesFractures, BoneFracture Fixation, InternalHumansMaleFemaleRetrospective StudiesAdultMiddle AgedTreatment OutcomeRange of Motion, ArticularAgedRadiographyYoung AdultFollow-Up StudiesFracture Healing

Stichwörter der Autor:innen

Clavicle hook plateCoracoclavicular ligamentsRadiological imagesScorpion plate®Unstable distal clavicle fractures

Autor:innen und Institutionen

  • Department of Orthopaedic Surgery, Tokai University Hachioji Hospital, 1838 Ishikawacho, Hachiojishi, Tokyo 192-0032, Japan; Department of Orthopaedic Surgery, Surgical Science, Tokai University School of Medicine, 143…
  • Department of Orthopaedic Surgery, Tokai University Hachioji Hospital, 1838 Ishikawacho, Hachiojishi, Tokyo 192-0032, Japan.
  • Department of Orthopaedic Surgery, Surgical Science, Tokai University School of Medicine, 143 Shimokasuya, Iseharashi, Kanagawa 259-1143, Japan.

Zitieren

APA

Takatori, N., Uchiyama, Y., Shimpuku, E., Imai, T., & Watanabe, M. (2025). Comparative clinical outcomes and radiological images of clavicle hook plate versus Scorpion Plate® for unstable distal clavicle fractures. Journal of Orthopaedic Science, 30(2), 307-312. https://doi.org/10.1016/j.jos.2024.06.003

Vancouver

Takatori N, Uchiyama Y, Shimpuku E, Imai T, Watanabe M. Comparative clinical outcomes and radiological images of clavicle hook plate versus Scorpion Plate® for unstable distal clavicle fractures. Journal of Orthopaedic Science. 2025;30(2):307-312. doi:10.1016/j.jos.2024.06.003

BibTeX
@article{Takatori2025,
  author = {Takatori, Naoki and Uchiyama, Yoshiyasu and Shimpuku, Eiji and Imai, Takeshi and Watanabe, Masahiko},
  title = {Comparative clinical outcomes and radiological images of clavicle hook plate versus Scorpion Plate® for unstable distal clavicle fractures},
  journal = {Journal of Orthopaedic Science},
  year = {2025},
  volume = {30},
  number = {2},
  pages = {307--312},
  doi = {10.1016/j.jos.2024.06.003}
}
Kostenlos starten →