Abstract (Originalsprache)

Aim

This in vitro study aimed to evaluate the trueness and precision of three-unit bridge restorations fabricated using different milling devices. Material and method A dental model prepared for bridge restorations in the right first premolar and first molar was scanned using a laboratory scanner (inEos X5, Dentsply Sirona). The data were imported into dental design software (DentalCAD 3.1 Rijeka; exocad GmbH) to create a bridge restoration design, saved as a reference (R-STL). Ten bridges were milled from polymethylmethacrylate blocks (Telio CAD LT A2 B55, Ivoclar Vivadent, Liechtenstein) using three milling devices: Cerec MC XL (C-STL), Cerec Primemill (P-STL), and inLab MC X5 (X-STL). The restorations were rescanned with an intraoral scanner (Cerec Primescan, Dentsply Sirona), and the datasets were analyzed using a 3D analysis program (Geomagic Control X v.2020.1, 3D Systems, NC, USA). Statistical analyses included one-way ANOVA, post hoc Tukey tests, and the Shapiro-Wilk test (α = 0.05).

Results

Significant differences in trueness were observed among the groups (p < 0.001), with the inLab MC X5 device (X-STL, RMS = 32 μm) showing the highest trueness and the Cerec MC XL group (C-STL, RMS = 44 μm) the lowest. No significant differences in precision were found (p = 0.117).

Conclusion

The choice of milling device significantly affects the trueness of three-unit bridge restorations, with the inLab MC X5 device producing the most accurate results. However, precision did not differ significantly among the devices.

Zitieren

APA

Dinçer, G., & Demirel, M. (2025). Comparative Evaluation of Trueness and Precision of PMMA Three-Unit Bridges Fabricated Using Three Milling Devices. Eurasian Dental Research. https://doi.org/10.62243/edr.1643661

Vancouver

Dinçer G, Demirel M. Comparative Evaluation of Trueness and Precision of PMMA Three-Unit Bridges Fabricated Using Three Milling Devices. Eurasian Dental Research. 2025. doi:10.62243/edr.1643661

BibTeX
@article{Diner2025,
  author = {Dinçer, Gökçen and Demirel, Münir},
  title = {Comparative Evaluation of Trueness and Precision of PMMA Three-Unit Bridges Fabricated Using Three Milling Devices},
  journal = {Eurasian Dental Research},
  year = {2025},
  doi = {10.62243/edr.1643661}
}
Kostenlos starten →