EUVIMEDEUVIMED entdecken
Vergleichsstudie

Impact of dental crowding on the trueness and precision of intraoral scanners: Comparison across different devices and techniques

Elabbas Elhussain, Oscar Figueras-Álvarez, Miguel Roig-Cayon, Jordi Ortega-Martínez, Carla Vidal-Ponsoda

American Journal of Orthodontics and Dentofacial Orthopedics · 2025-12 · 168 (6) · 670-681

DOI: 10.1016/j.ajodo.2025.08.004 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift American Journal of Orthodontics and Dentofacial Orthopedics, 2025-12. Verfasst von Elabbas Elhussain und 4 weiteren Autor:innen. Beteiligte Einrichtung: From the Department of Restorative Dentistry, Universitat Internacional de Catalunya, Barcelona, Spain. Hauptthemen laut MEDLINE: Dental Impression Technique, Malocclusion. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 25 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

INTRODUCTION: This study evaluated the impact of dental crowding on the trueness and precision of 6 intraoral scanners (Primescan [Dentsply Sirona], Medit i700 [Medit, Seoul, South Korea], Trios 3 [3Shape, Copenhagen, Denmark], iTero Element 5D [Align Technology, San Jose, Calif], Shining 3D [Shining 3D Technology, Hangzhou, China], and Helios 600 [Changzhou Sifary Medical Technology Co Ltd, Changzhou, China]) and extraoral scans of conventional silicone impressions using 3-dimensional-printed mandibular models with different crowding levels. METHODS: Mandibular models with no, slight, and severe crowding were scanned 5 times with each intraoral scanner and silicone impression. Trueness was assessed by comparing scans to a reference scan using Geomagic Control X, whereas precision was evaluated through intragroup comparisons. Root mean square (RMS) values were analyzed using 2-way analysis of variance and post-hoc least significant difference tests (α = 0.05). RESULTS: Crowding significantly affected both trueness (P = 0.001) and precision (P

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Dental Impression TechniqueMalocclusionHumansModels, DentalPrinting, Three-DimensionalImaging, Three-DimensionalMandibleSilicones

Substanzen

Silicones

Autor:innen und Institutionen

  • From the Department of Restorative Dentistry, Universitat Internacional de Catalunya, Barcelona, Spain.
  • From the Department of Restorative Dentistry, Universitat Internacional de Catalunya, Barcelona, Spain. Electronic address: ofigueras@uic.es.

Zitieren

APA

Elhussain, E., Figueras-Álvarez, O., Roig-Cayon, M., Ortega-Martínez, J., & Vidal-Ponsoda, C. (2025). Impact of dental crowding on the trueness and precision of intraoral scanners: Comparison across different devices and techniques. American Journal of Orthodontics and Dentofacial Orthopedics, 168(6), 670-681. https://doi.org/10.1016/j.ajodo.2025.08.004

Vancouver

Elhussain E, Figueras-Álvarez O, Roig-Cayon M, Ortega-Martínez J, Vidal-Ponsoda C. Impact of dental crowding on the trueness and precision of intraoral scanners: Comparison across different devices and techniques. American Journal of Orthodontics and Dentofacial Orthopedics. 2025;168(6):670-681. doi:10.1016/j.ajodo.2025.08.004

BibTeX
@article{Elhussain2025,
  author = {Elhussain, Elabbas and Figueras-Álvarez, Oscar and Roig-Cayon, Miguel and Ortega-Martínez, Jordi and Vidal-Ponsoda, Carla},
  title = {Impact of dental crowding on the trueness and precision of intraoral scanners: Comparison across different devices and techniques},
  journal = {American Journal of Orthodontics and Dentofacial Orthopedics},
  year = {2025},
  volume = {168},
  number = {6},
  pages = {670--681},
  doi = {10.1016/j.ajodo.2025.08.004}
}
Kostenlos starten →