EUVIMEDEUVIMED entdecken
Open Access · CC BY-SA 4.0

Measurement of Radiation Dose Received by the Eye Lens in Panoramic Examination Using a Thermoluminisence Dosimeter (TLD) in the Radiology Installation of Andalas University Hospital

Chairun Nisa, Wahdini Hanifah, Livia Ade Nansih, M.Biomed, Cicillia Artitin, Ananta Della Fitria

MSJ : Majority Science Journal · 15.05.2026 · 4 (2) · 77-87

DOI: 10.61942/msj.v4i2.594 ↗

Kurz gefasst

Fachartikel in der Zeitschrift MSJ : Majority Science Journal, online erschienen am 15.05.2026. Verfasst von Chairun Nisa und 5 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY-SA 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

A panoramic examination is an examination used to show the upper and lower jaws along with abnormalities in the oral area. The lens of the eye is a sensitive organ that is exposed to radiation during a panoramic examination. The lens of the eye that is exposed to radiation for a long time can cause cataracts that can develop to blindness, therefore to prevent cataracts, BAPETEN No. 6 of 2010 sets a deterministic threshold limit for the chance of cataracts at 15 mSv per year. This study aims to determine how much dose the lens of the eye receives during a panoramic examination and whether the dose received exceeds the established NBD. This type of research is an experimental quantitative study conducted at the Radiology Installation of Andalas University Hospital in September 2025 using a sample of 7 patients. The instruments and materials used are a panoramic machine, TLD and plaster isolation. Dose measurement is done by attaching the TLD to the patient's right and left eyelids then exposed using 73 kV, 10 mA and 10.8 s and then the TLD reading process is carried out. The measurement results obtained in nC units with the final result in the form of an effective dose compared with BAPETEN regulation No. 6 of 2010. The highest effective dose measurement result received by patient 2 was 0.13 mSv and the lowest in patient 1 was 0.095 mSv with an average dose received by all patients of 0.11 mSv. Based on BAPETEN regulation No. 6 of 2010, the deterministic threshold for the chance of cataracts is 15 mSv per year, so the range of effective dose values received by the patient is still within safe limits.

Zitieren

APA

Nisa, C., Hanifah, W., Nansih, L. A., M.Biomed, Artitin, C., & Fitria, A. D. (2026). Measurement of Radiation Dose Received by the Eye Lens in Panoramic Examination Using a Thermoluminisence Dosimeter (TLD) in the Radiology Installation of Andalas University Hospital. MSJ : Majority Science Journal, 4(2), 77-87. https://doi.org/10.61942/msj.v4i2.594

Vancouver

Nisa C, Hanifah W, Nansih LA, M.Biomed, Artitin C, Fitria AD. Measurement of Radiation Dose Received by the Eye Lens in Panoramic Examination Using a Thermoluminisence Dosimeter (TLD) in the Radiology Installation of Andalas University Hospital. MSJ : Majority Science Journal. 2026;4(2):77-87. doi:10.61942/msj.v4i2.594

BibTeX
@article{Nisa2026,
  author = {Nisa, Chairun and Hanifah, Wahdini and Nansih, Livia Ade and M.Biomed and Artitin, Cicillia and Fitria, Ananta Della},
  title = {Measurement of Radiation Dose Received by the Eye Lens in Panoramic Examination Using a Thermoluminisence Dosimeter (TLD) in the Radiology Installation of Andalas University Hospital},
  journal = {MSJ : Majority Science Journal},
  year = {2026},
  volume = {4},
  number = {2},
  pages = {77--87},
  doi = {10.61942/msj.v4i2.594}
}
Kostenlos starten →