EUVIMEDEUVIMED entdecken
Crossref

Total Ionizing Dose Measured With the Radiation Dosimeter Onboard the FY‐3E Satellite

B. Q. Zhang, G. H. Shen, C. Huang, Y. Sun, Y. Chang, J. T. Lü, P. F. Zhang, C. Q. Wang, Z. Chang, X. G. Zhang

Journal of Geophysical Research: Space Physics · 2025-01 · 130 (1)

DOI: 10.1029/2024ja033016 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Geophysical Research: Space Physics, online erschienen am 29.12.2024. Verfasst von B. Q. Zhang und 9 weiteren Autor:innen. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 32 Literaturangaben.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

FengYun‐3E (FY‐3E) was the first operational meteorological satellite in China in early morning orbit. The radiation dosimeter, which is part of the satellite's Space Environment Monitor (SEM), contains three probes to measure the total ionizing dose in the three directions of the satellite. Improvements in the dosimeter have been made to increase detection sensitivity. The RADFET, a radiation dose sensor, was calibrated using 60 Co radionuclide source to correlate its threshold voltage shift with the total ionizing dose. The improved dosimeter has a sensitivity of 0.06 rad (Si) to 0.45 rad (Si) in the measurement range. The flight data showed that the total ionizing dose within the FY‐3E satellite is anisotropic. The radiation dose rate in the +X and +Y directions increased by a few factors after the geomagnetic storms.

Zitieren

APA

Zhang, B. Q., Shen, G. H., Huang, C., Sun, Y., Chang, Y., Lü, J. T., Zhang, P. F., Wang, C. Q., Chang, Z., & Zhang, X. G. (2025). Total Ionizing Dose Measured With the Radiation Dosimeter Onboard the FY‐3E Satellite. Journal of Geophysical Research: Space Physics, 130(1). https://doi.org/10.1029/2024ja033016

Vancouver

Zhang BQ, Shen GH, Huang C, Sun Y, Chang Y, Lü JT, et al. Total Ionizing Dose Measured With the Radiation Dosimeter Onboard the FY‐3E Satellite. Journal of Geophysical Research: Space Physics. 2025;130(1). doi:10.1029/2024ja033016

BibTeX
@article{Zhang2025,
  author = {Zhang, B. Q. and Shen, G. H. and Huang, C. and Sun, Y. and Chang, Y. and Lü, J. T. and Zhang, P. F. and Wang, C. Q. and Chang, Z. and Zhang, X. G.},
  title = {Total Ionizing Dose Measured With the Radiation Dosimeter Onboard the FY‐3E Satellite},
  journal = {Journal of Geophysical Research: Space Physics},
  year = {2025},
  volume = {130},
  number = {1},
  doi = {10.1029/2024ja033016}
}
Kostenlos starten →