Fachartikel in der Zeitschrift Journal of Innovative Medical Technology, 2024. Verfasst von Kyonglin Park und 7 weiteren Autor:innen. Die Arbeit nennt 15 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: National Research Foundation of Korea, Ministry of Education, Korea Medical Device Development Fund.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background:The innovative use of the fluorescent dye indocyanine green (ICG) represents a significant advancement in surgical oncology.This study aimed to assess the feasibility of ICG-coated clips for enhancing tumor localization during minimally invasive gastrointestinal surgery.Materials and Methods: This study was conducted using female Yucatan miniature pigs, which approximate the human anatomy.Two pigs, each weighing 25-30 kg, underwent simulated gastrointestinal surgery.The ICG-coated clips used were VITTZ clips, which were not yet approved by the Korea Food and Drug Administration but utilized for research purposes.The visibility of the clips was evaluated using Stryker 1588 and 1688 Advanced Imaging Modalities platforms with SPY fluorescence technology.The procedure involved the endoscopic placement of clips in the stomach and colon, followed by laparoscopic visualization using ICG imaging systems. Result:The ICG-coated clips demonstrated superior visibility in both the stomach and colon.In the stomach, the Endoscopic Near-Infrared Visualization (ENV) mode revealed four bright spots on the gastric wall, with two distinctly visible in the overlay mode.Three bright fluorescent lights were discernible in the sigmoid colon using both imaging modes.The fluorescence intensity was slightly clearer in the ENV mode than in the overlay mode.Conclusion: ICG-coated clips can improve tumor localization, which is important during minimally invasive gastrointestinal surgery.This innovative approach may provide safer and more accurate alternatives.

Förderung

  • National Research Foundation of Korea
  • Ministry of Education
  • Korea Medical Device Development Fund

Zitieren

APA

Park, K., Kim, H., Kim, H., Choi, Y., Park, S., Park, J., Choi, M., & Sohn, D. K. (2024). Indocyanine-coated fluorescent clips for localization of gastrointestinal tumors. Journal of Innovative Medical Technology. https://doi.org/10.61940/jimt.240001

Vancouver

Park K, Kim H, Kim H, Choi Y, Park S, Park J, et al. Indocyanine-coated fluorescent clips for localization of gastrointestinal tumors. Journal of Innovative Medical Technology. 2024. doi:10.61940/jimt.240001

BibTeX
@article{Park2024,
  author = {Park, Kyonglin and Kim, Hongrae and Kim, Hyoung-Jun and Choi, Yongdoo and Park, Sung-Jae and Park, Jae-Suk and Choi, Min-Kyu and Sohn, Dae Kyung},
  title = {Indocyanine-coated fluorescent clips for localization of gastrointestinal tumors},
  journal = {Journal of Innovative Medical Technology},
  year = {2024},
  doi = {10.61940/jimt.240001}
}
Kostenlos starten →